A High‐Throughput Analytical Approach Using Polyaniline Doped With Oxalic Acid in Thin Film Solid‐Phase Microextraction for the Determination of Personal Care Products in Recreational Waters

ABSTRACT In this study, a high‐throughput analytical methodology was developed based on the thin film solid‐phase microextraction (TF‐SPME) technique, employing polyaniline (PAni) as the extractor phase for the determination of personal care products in recreational water samples. The compounds investigated included three parabens, methylparaben (MP), ethylparaben (EP), butylparaben (BP), the UV filter and benzophenone (BZP), with detection performed by high‐performance liquid chromatography with a diode‐array detector (HPLC‐DAD). Experimental conditions were optimized using univariate and multivariate approaches, evaluating the effects of the extractor phase, desorption solvent and time, sample pH, extraction time, and NaCl concentration. Optimal extraction conditions involved the use of PAni doped with oxalic acid, desorption in a mixture of ACN:MeOH (50:50) for 30 min, an extraction time of 150 min, sample pH adjusted to 7, and 20% NaCl. Calibration curves were performed in ultrapure water with determination coefficients greater than 0.9973. The limits of detection (LODs) and quantification (LOQs) were 1.5 and 5 µg L −1 , respectively, for all analytes. Intraday precision ranged from 2% to 19%, while inter‐day precision varied between 10% and 22%. Method accuracy was assessed through relative recovery experiments in a water sample from a swimming pool, with recoveries ranging from 74% to 109%. The developed method was applied to six recreational water samples. In three of them, the analyte concentrations were above the LOQ, while in the others, the analytes were not found or their concentrations were below the LOD.

Authors

Institutions

Publication Details

Journal
Journal of Separation Science
Published
2026-07-01
DOI
https://doi.org/10.1002/jssc.70478
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High‐Throughput Analytical Approach Using Polyaniline Doped With Oxalic Acid in Thin Film Solid‐Phase Microextraction for the Determination of Personal Care Products in Recreational Waters

Francielle Crocetta Turazzi, Amanda Vitória Santos, Eduardo Carasek, Guilherme Mariz de Oliveira Barra
Journal of Separation Science
Analytical chemistry methods development
article

A High‐Throughput Analytical Approach Using Polyaniline Doped With Oxalic Acid in Thin Film Solid‐Phase Microextraction for the Determination of Personal Care Products in Recreational Waters

Francielle Crocetta Turazzi, Amanda Vitória Santos, Eduardo Carasek, Guilherme Mariz de Oliveira Barra
article en

Abstract

ABSTRACT In this study, a high‐throughput analytical methodology was developed based on the thin film solid‐phase microextraction (TF‐SPME) technique, employing polyaniline (PAni) as the extractor phase for the determination of personal care products in recreational water samples. The compounds investigated included three parabens, methylparaben (MP), ethylparaben (EP), butylparaben (BP), the UV filter and benzophenone (BZP), with detection performed by high‐performance liquid chromatography with a diode‐array detector (HPLC‐DAD). Experimental conditions were optimized using univariate and multivariate approaches, evaluating the effects of the extractor phase, desorption solvent and time, sample pH, extraction time, and NaCl concentration. Optimal extraction conditions involved the use of PAni doped with oxalic acid, desorption in a mixture of ACN:MeOH (50:50) for 30 min, an extraction time of 150 min, sample pH adjusted to 7, and 20% NaCl. Calibration curves were performed in ultrapure water with determination coefficients greater than 0.9973. The limits of detection (LODs) and quantification (LOQs) were 1.5 and 5 µg L −1 , respectively, for all analytes. Intraday precision ranged from 2% to 19%, while inter‐day precision varied between 10% and 22%. Method accuracy was assessed through relative recovery experiments in a water sample from a swimming pool, with recoveries ranging from 74% to 109%. The developed method was applied to six recreational water samples. In three of them, the analyte concentrations were above the LOQ, while in the others, the analytes were not found or their concentrations were below the LOD.

Journal of Separation ScienceVol. 49(7)
Universidade Federal de Santa Catarina (BR)
Clean water and sanitation
Openalex Percentile: Top 10%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.