Pushing the boundaries of robotic computed tomography: automated twin-robot CT scan with maximum reachability

Computed tomography is a widely used imaging method for non-destructive testing. However, standard CT systems face fundamental limitations when scanning large objects such as car bodies, which must fit between the X-ray source and detector, both of which need freedom of movement around the specimen. Twin-robotic CT systems with high degrees of freedom address these limitations by enabling free positioning of the X-ray source and detector in space, making non-destructive CT testing of large objects feasible. However, achieving collision-free positioning of the robots is a challenging problem that is often neglected in theoretical representations of twin-robot CT configurations. This paper presents a systematic methodology for performing region-of-interest scans on large objects. The approach exploits the test object's geometry to determine robot reachability, which serves as the foundation for trajectory planning by incorporating accessible regions. By leveraging both rotational and translational degrees of freedom, including variable source-detector distances and detector rotations, the methodology expands the range of collision-free poses, thereby increasing reachability and enabling more flexible trajectory design. The methodology is modular and adapts to arbitrary system configurations and test samples via computer-aided design (CAD)-based geometry definition, where the test object determines the collision-free workspace. It is demonstrated on a BMW 4-series body-in-white through comprehensive batch simulation across 273 Region of Interest (ROI) positions, evaluating reachability improvements achieved through the introduced degrees of freedom using a data completeness trajectory optimization criterion.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-07-02
DOI
https://doi.org/10.1038/s41598-026-56718-9
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pushing the boundaries of robotic computed tomography: automated twin-robot CT scan with maximum reachability

Gabriel Herl, Jonas Schnitzer, Vinayaka Raju Sathyanarayana Raju, Nihat Emir Erdebil et al.
Scientific Reports
Advanced X-ray and CT Imaging
article

Pushing the boundaries of robotic computed tomography: automated twin-robot CT scan with maximum reachability

Gabriel Herl, Jonas Schnitzer, Vinayaka Raju Sathyanarayana Raju, Nihat Emir Erdebil, Andreas Maier
article en

Abstract

Computed tomography is a widely used imaging method for non-destructive testing. However, standard CT systems face fundamental limitations when scanning large objects such as car bodies, which must fit between the X-ray source and detector, both of which need freedom of movement around the specimen. Twin-robotic CT systems with high degrees of freedom address these limitations by enabling free positioning of the X-ray source and detector in space, making non-destructive CT testing of large objects feasible. However, achieving collision-free positioning of the robots is a challenging problem that is often neglected in theoretical representations of twin-robot CT configurations. This paper presents a systematic methodology for performing region-of-interest scans on large objects. The approach exploits the test object's geometry to determine robot reachability, which serves as the foundation for trajectory planning by incorporating accessible regions. By leveraging both rotational and translational degrees of freedom, including variable source-detector distances and detector rotations, the methodology expands the range of collision-free poses, thereby increasing reachability and enabling more flexible trajectory design. The methodology is modular and adapts to arbitrary system configurations and test samples via computer-aided design (CAD)-based geometry definition, where the test object determines the collision-free workspace. It is demonstrated on a BMW 4-series body-in-white through comprehensive batch simulation across 273 Region of Interest (ROI) positions, evaluating reachability improvements achieved through the introduced degrees of freedom using a data completeness trajectory optimization criterion.

Scientific ReportsVol. 16(1)
BMW (Germany) (DE), Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), TU Dortmund University (DE), Technical University of Munich (DE), Deggendorf Institute of Technology (DE)
Friedrich-Alexander-Universität Erlangen-Nürnberg
Peace, Justice and strong institutions
Openalex Percentile: Top 13%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.