Development of a DC-Coupled Three-Phase Grid-Connected Solar Photovoltaic Integrated Battery Energy Storage System with Peak Shaving and Valley-Filling Control

This study addresses the power dispatching of a DC-coupled three-phase grid-connected photovoltaic (PV) and energy storage-integrated system by proposing a peak shaving and valley-filling control architecture based on time-of-use (TOU) pricing. This research involves achieving maximum power-point tracking (MPPT) for PVMAs using a boost converter combined with the perturb and observe (P&O) method. A lithium-iron phosphate battery pack is integrated into the DC link via a bidirectional buck-boost converter, where charging and discharging control is executed according to peak and off-peak periods to regulate and stabilize the DC link voltage. Furthermore, bidirectional power flow control for peak and off-peak electricity consumption is realized using hysteresis current control and sinusoidal pulse-width modulation (SPWM) technologies within a smart inverter. By integrating the aforementioned power control architecture, the grid system can store energy from the utility during off-peak hours and release the stored energy during peak hours to reduce the load demand on the utility side. Initially, a simulation environment was established using Matlab/Simulink (2024b version) software, followed by control verification of the proposed system on a physical platform. The simulation and experimental results confirm that the integrated control architecture can precisely control the system’s DC link voltage at 800 V and stabilize the grid-connected AC voltage at an effective value (RMS) of 380 V. Moreover, under conditions of peak/off-peak switching and load variations, the system effectively demonstrates its stability and efficacy in performing valley filling and peak shaving. The proposed strategy achieves a power factor above 0.99 and a total harmonic distortion (THD) below 5%, regulates the DC-link voltage at 800 V with a steady-state error within 1.75%, and prevents up to 66.4 kWh of over-contract energy consumption per day under a 35 kW contract capacity, thereby contributing to sustainable energy management and economic savings.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2026-07-02
DOI
https://doi.org/10.3390/su18136738
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a DC-Coupled Three-Phase Grid-Connected Solar Photovoltaic Integrated Battery Energy Storage System with Peak Shaving and Valley-Filling Control

Kuei‐Hsiang Chao, Yuhua Wang, Chang-De Wu
Sustainability
Microgrid Control and Optimization
article

Development of a DC-Coupled Three-Phase Grid-Connected Solar Photovoltaic Integrated Battery Energy Storage System with Peak Shaving and Valley-Filling Control

Kuei‐Hsiang Chao, Yuhua Wang, Chang-De Wu
article en

Abstract

This study addresses the power dispatching of a DC-coupled three-phase grid-connected photovoltaic (PV) and energy storage-integrated system by proposing a peak shaving and valley-filling control architecture based on time-of-use (TOU) pricing. This research involves achieving maximum power-point tracking (MPPT) for PVMAs using a boost converter combined with the perturb and observe (P&O) method. A lithium-iron phosphate battery pack is integrated into the DC link via a bidirectional buck-boost converter, where charging and discharging control is executed according to peak and off-peak periods to regulate and stabilize the DC link voltage. Furthermore, bidirectional power flow control for peak and off-peak electricity consumption is realized using hysteresis current control and sinusoidal pulse-width modulation (SPWM) technologies within a smart inverter. By integrating the aforementioned power control architecture, the grid system can store energy from the utility during off-peak hours and release the stored energy during peak hours to reduce the load demand on the utility side. Initially, a simulation environment was established using Matlab/Simulink (2024b version) software, followed by control verification of the proposed system on a physical platform. The simulation and experimental results confirm that the integrated control architecture can precisely control the system’s DC link voltage at 800 V and stabilize the grid-connected AC voltage at an effective value (RMS) of 380 V. Moreover, under conditions of peak/off-peak switching and load variations, the system effectively demonstrates its stability and efficacy in performing valley filling and peak shaving. The proposed strategy achieves a power factor above 0.99 and a total harmonic distortion (THD) below 5%, regulates the DC-link voltage at 800 V with a steady-state error within 1.75%, and prevents up to 66.4 kWh of over-contract energy consumption per day under a 35 kW contract capacity, thereby contributing to sustainable energy management and economic savings.

SustainabilityVol. 18(13)
National Chin-Yi University of Technology (TW)
Openalex Percentile: Top 9%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.