Liver Diffusion Weighted MRI: Effect of Iron Overload on Apparent Diffusion Coefficient

ABSTRACT We assessed the effect of hepatic iron levels on liver apparent diffusion coefficient (ADC) values assessed by magnetic resonance imaging (MRI) and the influence of different b ‐values on the extent of this association. We prospectively enrolled 110 patients (60 women, 33.05 ± 7.86 years) with beta‐thalassemia. Single‐shot echoplanar diffusion‐weighted imaging (DWI) with different b values was acquired, and ADC_200 ( b ‐values 0/200 s/mm 2 ), ADC_600 ( b ‐values 0/600 s/mm 2 ), and ADC_1000 ( b ‐values 0/1000 s/mm 2 ) were obtained. Liver T2* values were measured with a gradient–echo multiecho sequence and were converted into liver iron concentration (LIC) values. There was a significant difference among the three different ADC values ( p < 0.0001). Mean MRI LIC values were 7.99 ± 10.09 mg/g dw, and 64 (58.2%) patients had liver iron overload (LIC > 3 mg/g dw). Significant negative correlation was found between MRI LIC values and ADC_200 values ( R = −0.284, p = 0.003), ADC_600 values ( R = −0.645, p < 0.00001), and ADC_1000 values ( R = −0.842, p < 0.0001). MRI LIC was more strongly correlated with both ADC_600 and ADC_1000 than with ADC_200 ( p < 0.00001 for both comparisons) and with ADC_600 than with ADC_200 ( p < 0.0001). ADC_200 values were comparable between patients without and with liver iron overload (2.11 ± 0.53 vs. 1.87 ± 0.89 × 10–3 mm 2 /s, p = 0.081), while patients with liver iron overload had significantly decreased ADC_600 values (0.91 ± 0.72 vs. 1.52 ± 0.49 × 10–3 mm 2 /s, p < 0.0001), and ADC_1000 values (0.48 ± 0.38 vs. 1.23 ± 0.23 × 10–3 mm 2 /s, p < 0.0001). In conclusion, the demonstrated inverse correlation between LIC and liver ADC values, accentuated at higher diffusion b ‐values, has relevant clinical implications, indicating that liver iron overload acts as a confounding factor in quantitative DWI and should be accounted for to avoid misinterpretation of liver ADC measurements in diagnostic and therapeutic workflows.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-07-01
DOI
https://doi.org/10.1002/nbm.70351
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Liver Diffusion Weighted MRI: Effect of Iron Overload on Apparent Diffusion Coefficient

Antonella Meloni, Michele Santodirocco, Gennaro Restaino, Alberto Clemente et al.
NMR in Biomedicine
MRI in cancer diagnosis
article

Liver Diffusion Weighted MRI: Effect of Iron Overload on Apparent Diffusion Coefficient

Antonella Meloni, Michele Santodirocco, Gennaro Restaino, Alberto Clemente, Laura Pistoia, Roberta Renni, Massimiliano Missere, Giuseppina Sallustio, Vincenzo Positano, Maria Grazia Roberti, Marilena Serra
article en

Abstract

ABSTRACT We assessed the effect of hepatic iron levels on liver apparent diffusion coefficient (ADC) values assessed by magnetic resonance imaging (MRI) and the influence of different b ‐values on the extent of this association. We prospectively enrolled 110 patients (60 women, 33.05 ± 7.86 years) with beta‐thalassemia. Single‐shot echoplanar diffusion‐weighted imaging (DWI) with different b values was acquired, and ADC_200 ( b ‐values 0/200 s/mm 2 ), ADC_600 ( b ‐values 0/600 s/mm 2 ), and ADC_1000 ( b ‐values 0/1000 s/mm 2 ) were obtained. Liver T2* values were measured with a gradient–echo multiecho sequence and were converted into liver iron concentration (LIC) values. There was a significant difference among the three different ADC values ( p < 0.0001). Mean MRI LIC values were 7.99 ± 10.09 mg/g dw, and 64 (58.2%) patients had liver iron overload (LIC > 3 mg/g dw). Significant negative correlation was found between MRI LIC values and ADC_200 values ( R = −0.284, p = 0.003), ADC_600 values ( R = −0.645, p < 0.00001), and ADC_1000 values ( R = −0.842, p < 0.0001). MRI LIC was more strongly correlated with both ADC_600 and ADC_1000 than with ADC_200 ( p < 0.00001 for both comparisons) and with ADC_600 than with ADC_200 ( p < 0.0001). ADC_200 values were comparable between patients without and with liver iron overload (2.11 ± 0.53 vs. 1.87 ± 0.89 × 10–3 mm 2 /s, p = 0.081), while patients with liver iron overload had significantly decreased ADC_600 values (0.91 ± 0.72 vs. 1.52 ± 0.49 × 10–3 mm 2 /s, p < 0.0001), and ADC_1000 values (0.48 ± 0.38 vs. 1.23 ± 0.23 × 10–3 mm 2 /s, p < 0.0001). In conclusion, the demonstrated inverse correlation between LIC and liver ADC values, accentuated at higher diffusion b ‐values, has relevant clinical implications, indicating that liver iron overload acts as a confounding factor in quantitative DWI and should be accounted for to avoid misinterpretation of liver ADC measurements in diagnostic and therapeutic workflows.

NMR in BiomedicineVol. 39(8)
Università Cattolica del Sacro Cuore (IT), Casa Sollievo della Sofferenza (IT), Ospedale Santa Chiara (IT), Ospedali Riuniti di Foggia (IT), Consorzio Milano Ricerche (IT), Ospedale Vito Fazzi (IT), Fondazione Toscana Gabriele Monasterio (IT), Regione Toscana
Openalex Percentile: Top 7%
MRI in cancer diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.