Electrochemical analysis of tetracycline in drug formulations with glutardialdehyde-Fe2O3 modified glassy carbon electrode

In this study, a glutardialdehyde-Fe2O3 modified glassy carbon electrode (GA2–Fe2O3/GCE) was used as a sensor for the electrochemical analysis of tetracycline (TC) in drug formulations. The electrochemical behavior of TC on GA2-Fe2O3/GCE was investigated using cyclic voltammetry (CV), while the quantitative determination was performed via differential pulse voltammetry (DPV). After optimizing the experimental conditions, the linear working range, limit of (LOD) detection, and limit of quantification (LOQ) of the GA2-Fe2O3/GCE electrode developed for the electrochemical analysis of TC were found to be 1.0 × 10−6–2.0 × 10−5 M and 2.0 × 10−5–9.9 × 10−6 M; 4.78 × 10−7 M; 1.59 × 10−6 M, respectively. In the sensor application study conducted on a Tetra® Gensenta tablet to demonstrate the applicability of the developed method, the linear working range, LOD, and LOQ values of the sensor were found to be 1.0 × 10−6–14.8 × 10−5 M; 5.72 × 10−7 M and 1.74 × 10−6 M, respectively. The applicability of the method was demonstrated through tablet recovery studies, and the tablet recovery ratio was determined to be 100.94%.

Authors

Institutions

Publication Details

Journal
Chemical Papers
Published
2026-07-02
DOI
https://doi.org/10.1007/s11696-026-05240-3
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical analysis of tetracycline in drug formulations with glutardialdehyde-Fe2O3 modified glassy carbon electrode

Yeliz İpek, Berna Koçak
Chemical Papers
Electrochemical sensors and biosensors
article

Electrochemical analysis of tetracycline in drug formulations with glutardialdehyde-Fe2O3 modified glassy carbon electrode

Yeliz İpek, Berna Koçak
article en

Abstract

In this study, a glutardialdehyde-Fe2O3 modified glassy carbon electrode (GA2–Fe2O3/GCE) was used as a sensor for the electrochemical analysis of tetracycline (TC) in drug formulations. The electrochemical behavior of TC on GA2-Fe2O3/GCE was investigated using cyclic voltammetry (CV), while the quantitative determination was performed via differential pulse voltammetry (DPV). After optimizing the experimental conditions, the linear working range, limit of (LOD) detection, and limit of quantification (LOQ) of the GA2-Fe2O3/GCE electrode developed for the electrochemical analysis of TC were found to be 1.0 × 10−6–2.0 × 10−5 M and 2.0 × 10−5–9.9 × 10−6 M; 4.78 × 10−7 M; 1.59 × 10−6 M, respectively. In the sensor application study conducted on a Tetra® Gensenta tablet to demonstrate the applicability of the developed method, the linear working range, LOD, and LOQ values of the sensor were found to be 1.0 × 10−6–14.8 × 10−5 M; 5.72 × 10−7 M and 1.74 × 10−6 M, respectively. The applicability of the method was demonstrated through tablet recovery studies, and the tablet recovery ratio was determined to be 100.94%.

Chemical Papers
Munzur University (TR)
Munzur Üniversitesi
Openalex Percentile: Top 12%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electrochemical analysis of tetracycline in drug formulations with glutardialdehyde-Fe2O3 modified glassy carbon electrode — Yeliz İpek, Berna Koçak · Chemical Papers (2026) | TGRS Research Map | TGRS