Effect of Titanium Dioxide (TiO2) Incorporation on the Properties of Glass Ionomer Cements: A Systematic Review

This systematic review aimed to investigate the effect of titanium dioxide (TiO2) incorporation on the mechanical, physicochemical, and biological properties of conventional glass ionomer cements (GICs). A systematic search was conducted in June 2026 in PubMed, Scopus, Embase, Web of Science and WorldCat databases. Search terms included combinations of glass ionomer AND titanium dioxide OR TiO2 OR titanium oxide OR titanium nanotubes OR titanium nanoparticles. The study selection process followed the PRISMA guideline and was organized according to the PECO framework. The search yielded the identification of 475 articles, of which 34 met the eligibility criteria. The included studies investigated different TiO2 forms, concentrations, and commercial GIC formulations. Many studies reported improvements in compressive strength, surface microhardness, fracture toughness, and antibacterial activity following TiO2 incorporation. However, the findings were heterogeneous. Several studies reported no statistically significant differences or contradictory outcomes, particularly regarding flexural strength, fluoride release, cytocompatibility, and antibacterial performance. Beneficial effects were most frequently observed at TiO2 concentrations between 3 and 5 wt%, whereas higher concentrations were occasionally associated with nanoparticle agglomeration and reduced material performance. Variability among studies was likely influenced by differences in TiO2 characteristics, concentration, testing protocols, and GIC formulation. Overall, TiO2 incorporation appears to be a promising approach for enhancing selected properties of conventional GICs. However, further standardized studies are required to confirm the consistency and clinical relevance of these effects.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-07-02
DOI
https://doi.org/10.3390/ma19132827
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Titanium Dioxide (TiO2) Incorporation on the Properties of Glass Ionomer Cements: A Systematic Review

Jacek Matys, Maciej Dobrzyński, Julia Kensy, Agata Małyszek et al.
Materials
Dental materials and restorations
article

Effect of Titanium Dioxide (TiO2) Incorporation on the Properties of Glass Ionomer Cements: A Systematic Review

Jacek Matys, Maciej Dobrzyński, Julia Kensy, Agata Małyszek, Agnieszka Kotela, Jakub Wenderski
article en

Abstract

This systematic review aimed to investigate the effect of titanium dioxide (TiO2) incorporation on the mechanical, physicochemical, and biological properties of conventional glass ionomer cements (GICs). A systematic search was conducted in June 2026 in PubMed, Scopus, Embase, Web of Science and WorldCat databases. Search terms included combinations of glass ionomer AND titanium dioxide OR TiO2 OR titanium oxide OR titanium nanotubes OR titanium nanoparticles. The study selection process followed the PRISMA guideline and was organized according to the PECO framework. The search yielded the identification of 475 articles, of which 34 met the eligibility criteria. The included studies investigated different TiO2 forms, concentrations, and commercial GIC formulations. Many studies reported improvements in compressive strength, surface microhardness, fracture toughness, and antibacterial activity following TiO2 incorporation. However, the findings were heterogeneous. Several studies reported no statistically significant differences or contradictory outcomes, particularly regarding flexural strength, fluoride release, cytocompatibility, and antibacterial performance. Beneficial effects were most frequently observed at TiO2 concentrations between 3 and 5 wt%, whereas higher concentrations were occasionally associated with nanoparticle agglomeration and reduced material performance. Variability among studies was likely influenced by differences in TiO2 characteristics, concentration, testing protocols, and GIC formulation. Overall, TiO2 incorporation appears to be a promising approach for enhancing selected properties of conventional GICs. However, further standardized studies are required to confirm the consistency and clinical relevance of these effects.

MaterialsVol. 19(13)
Wrocław University of Environmental and Life Sciences (PL), Military Hospital (PK), Wroclaw Medical University (PL)
Uniwersytet Medyczny im. Piastów Slaskich we Wroclawiu
Openalex Percentile: Top 7%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.