Accuracy of teeth positioning in bonded three-dimensionally printed complete dentures: an in vitro study

PURPOSE: While the mechanical and material properties of 3D printed denture components have been extensively studied, the accuracy implications of the assembly process, specifically the bonding of separately printed teeth onto the denture base, remain insufficiently investigated. Positional distortion introduced at this stage could potentially result in downstream occlusal discrepancies. This study therefore investigated the accuracy of different 3D printing materials, methods (monoblock versus assembled) and assembly configurations (complete arch versus segmented) in the fabrication of 3D printed dentures. METHODS: Four groups of dentures (M, T, F, S; n = 15) were fabricated. M and T were printed monoblock units using model resin and tooth-coloured resin, respectively. F and S involved separate printing of denture bases and teeth, followed by bonding. Teeth were fabricated as a full arch in F and in three segments in S. All specimens were produced under standardised conditions. Digitized samples compared to a reference model using a surface-matching software. Tooth positional deviations were assessed as a complete arch and in sextants. Data was analysed using two-way analysis of variance and post-hoc tests (α = 0.05). RESULTS: For complete arch analysis, Groups M and T demonstrated significantly lower deviations than Groups F and S (p = 0.001), with no significant differences within monoblock or assembled groups (p > 0.05). Sextant analysis showed consistent findings across all regions, with monoblock groups demonstrating superior accuracy. CONCLUSION: Monoblock 3D-printed dentures exhibited greater positional accuracy than assembled dentures. Although deviations were within clinically acceptable thresholds, further clinical studies are required to determine their impact on occlusion and patient outcomes.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-07-02
DOI
https://doi.org/10.1186/s12903-026-09125-5
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of teeth positioning in bonded three-dimensionally printed complete dentures: an in vitro study

Chow Kye Sern Bryan, Yu Na, Chia Ai Ping Vanessa, Tan Zhi Hui Janice
BMC Oral Health
Dental materials and restorations
article

Accuracy of teeth positioning in bonded three-dimensionally printed complete dentures: an in vitro study

Chow Kye Sern Bryan, Yu Na, Chia Ai Ping Vanessa, Tan Zhi Hui Janice
article en

Abstract

PURPOSE: While the mechanical and material properties of 3D printed denture components have been extensively studied, the accuracy implications of the assembly process, specifically the bonding of separately printed teeth onto the denture base, remain insufficiently investigated. Positional distortion introduced at this stage could potentially result in downstream occlusal discrepancies. This study therefore investigated the accuracy of different 3D printing materials, methods (monoblock versus assembled) and assembly configurations (complete arch versus segmented) in the fabrication of 3D printed dentures. METHODS: Four groups of dentures (M, T, F, S; n = 15) were fabricated. M and T were printed monoblock units using model resin and tooth-coloured resin, respectively. F and S involved separate printing of denture bases and teeth, followed by bonding. Teeth were fabricated as a full arch in F and in three segments in S. All specimens were produced under standardised conditions. Digitized samples compared to a reference model using a surface-matching software. Tooth positional deviations were assessed as a complete arch and in sextants. Data was analysed using two-way analysis of variance and post-hoc tests (α = 0.05). RESULTS: For complete arch analysis, Groups M and T demonstrated significantly lower deviations than Groups F and S (p = 0.001), with no significant differences within monoblock or assembled groups (p > 0.05). Sextant analysis showed consistent findings across all regions, with monoblock groups demonstrating superior accuracy. CONCLUSION: Monoblock 3D-printed dentures exhibited greater positional accuracy than assembled dentures. Although deviations were within clinically acceptable thresholds, further clinical studies are required to determine their impact on occlusion and patient outcomes.

BMC Oral Health
Duke-NUS Medical School (SG), National Dental Centre of Singapore (SG)
Openalex Percentile: Top 7%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.