Assessment of Shallow Geothermal Energy for Greenhouse Cooling in a Hot Arid Climate Using Measured Subsurface Temperatures

Greenhouse cooling in hot arid regions such as Qatar is challenged by high ambient temperatures and solar loads. This study evaluates shallow geothermal coupling as a heat rejection mechanism for greenhouse cooling using measured subsurface temperature data and numerical modeling. Underground measurements indicate thermally stable soil conditions at approximately 30 °C below a depth of about 7 m. These data are integrated into a COMSOL Multiphysics model of a mechanically cooled greenhouse operating under cooling-dominated conditions. For the modeled reference case, a peak sensible cooling load of approximately 14 kW is considered. Simulations show that geothermal coupling reduces the effective heat rejection temperature by approximately 15 °C compared to air-based rejection, thereby moderating peak cooling demand under extreme summer conditions.

Authors

Institutions

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-07-01
DOI
https://doi.org/10.1051/e3sconf/202672005002/pdf
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Shallow Geothermal Energy for Greenhouse Cooling in a Hot Arid Climate Using Measured Subsurface Temperatures

Mohammed Al-Azba, Ahmed Abotaleb
Springer Link (Chiba Institute of Technology)
Geothermal Energy Systems and Applications
article

Assessment of Shallow Geothermal Energy for Greenhouse Cooling in a Hot Arid Climate Using Measured Subsurface Temperatures

Mohammed Al-Azba, Ahmed Abotaleb
article en

Abstract

Greenhouse cooling in hot arid regions such as Qatar is challenged by high ambient temperatures and solar loads. This study evaluates shallow geothermal coupling as a heat rejection mechanism for greenhouse cooling using measured subsurface temperature data and numerical modeling. Underground measurements indicate thermally stable soil conditions at approximately 30 °C below a depth of about 7 m. These data are integrated into a COMSOL Multiphysics model of a mechanically cooled greenhouse operating under cooling-dominated conditions. For the modeled reference case, a peak sensible cooling load of approximately 14 kW is considered. Simulations show that geothermal coupling reduces the effective heat rejection temperature by approximately 15 °C compared to air-based rejection, thereby moderating peak cooling demand under extreme summer conditions.

Springer Link (Chiba Institute of Technology)
Qatar Foundation (QA)
Climate action
Openalex Percentile: Top 20%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of Shallow Geothermal Energy for Greenhouse Cooling in a Hot Arid Climate Using Measured Subsurface Temperatures — Mohammed Al-Azba, Ahmed Abotaleb · Springer Link (Chiba Institute of Technology) (2026) | TGRS Research Map | TGRS