Prototype Scintillating-Fiber SiPM-Based Beam Monitor for Conventional and FLASH Proton Therapy

The development of FLASH particle therapy, especially proton therapy, characterized by ultra-high dose rates (>40 Gy/s), presents significant challenges for dosimetry and beam monitoring. For example, ionization chambers (ICs) exhibit charge recombination effects leading to saturation, and other passive detectors cannot be used for real-time monitoring. This paper presents the idea, simulations and the preliminary prototype of a scintillating-fibers SiPM-based dosimeter for both high-flux and conventional dose-rate proton beam therapy. The prototype is based on 1 mm diameter plastic scintillating fibers, coupled to Silicon Photomultipliers (SiPMs). We estimated the interactions and the produced light signal within the fibers by the protons and towards the photodetectors using a semi-analytical model combining SRIM and analytical calculations. We estimated a light signal reaching the SiPMs in the range of 107–1011 photons (in a 50 ms beam pulse), for proton energies in the range 70–228 MeV, between the minimum and maximum beam current levels for conventional and FLASH conditions. Results highlight the very large dynamic range needed to be compatible with conventional and FLASH regimes. We also evaluated the linearity limits of the SiPMs and of the scintillating fibers. Finally, we preliminarily validated a reduced prototype version with a proton beam, demonstrating a good linearity of the system.

Authors

Institutions

Publication Details

Journal
Instruments
Published
2026-07-02
DOI
https://doi.org/10.3390/instruments10030036
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prototype Scintillating-Fiber SiPM-Based Beam Monitor for Conventional and FLASH Proton Therapy

Fabio Acerbi, B. Di Ruzza, Georgios Mystridis
Instruments
Radiation Therapy and Dosimetry
article

Prototype Scintillating-Fiber SiPM-Based Beam Monitor for Conventional and FLASH Proton Therapy

Fabio Acerbi, B. Di Ruzza, Georgios Mystridis
article en

Abstract

The development of FLASH particle therapy, especially proton therapy, characterized by ultra-high dose rates (>40 Gy/s), presents significant challenges for dosimetry and beam monitoring. For example, ionization chambers (ICs) exhibit charge recombination effects leading to saturation, and other passive detectors cannot be used for real-time monitoring. This paper presents the idea, simulations and the preliminary prototype of a scintillating-fibers SiPM-based dosimeter for both high-flux and conventional dose-rate proton beam therapy. The prototype is based on 1 mm diameter plastic scintillating fibers, coupled to Silicon Photomultipliers (SiPMs). We estimated the interactions and the produced light signal within the fibers by the protons and towards the photodetectors using a semi-analytical model combining SRIM and analytical calculations. We estimated a light signal reaching the SiPMs in the range of 107–1011 photons (in a 50 ms beam pulse), for proton energies in the range 70–228 MeV, between the minimum and maximum beam current levels for conventional and FLASH conditions. Results highlight the very large dynamic range needed to be compatible with conventional and FLASH regimes. We also evaluated the linearity limits of the SiPMs and of the scintillating fibers. Finally, we preliminarily validated a reduced prototype version with a proton beam, demonstrating a good linearity of the system.

InstrumentsVol. 10(3)
University of Foggia (IT), Fondazione Bruno Kessler (IT)
European Commission
Affordable and clean energy
Openalex Percentile: Top 8%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Prototype Scintillating-Fiber SiPM-Based Beam Monitor for Conventional and FLASH Proton Therapy — Fabio Acerbi, B. Di Ruzza, et al. · Instruments (2026) | TGRS Research Map | TGRS