Balloon Sizing-Guided Valve Selection for Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve

Valve size selection for transcatheter aortic valve replacement using a balloon-expandable valve in a bicuspid aortic valve (BAV) involves a trade-off among the risks of aortic rupture, residual paravalvular leak, and inadequate valve expansion. We report 2 cases of type 1 BAVs with a tapered configuration that created challenges regarding valve size selection. Two consecutive valve sizes were considered based on multidetector computed tomography measurements. Therefore, predilatation with contrast injection was performed using a balloon that was slightly smaller than the smaller of the 2 valve sizes. These cases suggest that a smaller valve should be selected when balloon indentation is observed without contrast backflow into the left ventricle because selecting the larger valve may result in insufficient expansion. Balloon predilatation with contrast injection may be a useful strategy for determining the appropriate valve size for transcatheter aortic valve replacement using a balloon-expandable valve in type 1 BAVs with a tapered configuration.

Authors

Institutions

Publication Details

Journal
JACC Case Reports
Published
2026-07-01
DOI
https://doi.org/10.1016/j.jaccas.2026.108896
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Balloon Sizing-Guided Valve Selection for Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve

Yoshiko Munehisa, Makoto Saigan, Yusuke Enta, Yusuke Toki et al.
JACC Case Reports
Cardiac Valve Diseases and Treatments
article

Balloon Sizing-Guided Valve Selection for Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve

Yoshiko Munehisa, Makoto Saigan, Yusuke Enta, Yusuke Toki, Masaki Nakashima, Yuhei Hasegawa, Natsuko Satomi, Norio Tada, Yun Teng, Daishi Tazawa
article en

Abstract

Valve size selection for transcatheter aortic valve replacement using a balloon-expandable valve in a bicuspid aortic valve (BAV) involves a trade-off among the risks of aortic rupture, residual paravalvular leak, and inadequate valve expansion. We report 2 cases of type 1 BAVs with a tapered configuration that created challenges regarding valve size selection. Two consecutive valve sizes were considered based on multidetector computed tomography measurements. Therefore, predilatation with contrast injection was performed using a balloon that was slightly smaller than the smaller of the 2 valve sizes. These cases suggest that a smaller valve should be selected when balloon indentation is observed without contrast backflow into the left ventricle because selecting the larger valve may result in insufficient expansion. Balloon predilatation with contrast injection may be a useful strategy for determining the appropriate valve size for transcatheter aortic valve replacement using a balloon-expandable valve in type 1 BAVs with a tapered configuration.

JACC Case Reports
Sendai Kousei Hospital (JP)
Openalex Percentile: Top 7%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Balloon Sizing-Guided Valve Selection for Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve — Yoshiko Munehisa, Makoto Saigan, et al. · JACC Case Reports (2026) | TGRS Research Map | TGRS