Data-driven prediction and thermodynamic performance assessment of industrial cooling towers using advanced machine learning algorithms

Cooling towers are an important part of the thermal system in industries, where they are used to remove unwanted heat and help maintain the proper performance of the machines. Four machine learning algorithms, namely random forest, support vector machine (SVM), decision tree, and AdaBoost are proposed in this paper for the performance forecasting of cooling towers. for the performance forecasting of cooling towers. These models were built in Python with the help of the following operational parameters: inlet water temperature (32-41°C), ambient air temperature (14-32°C), and relative humidity (35-92%). All the essential performance measures like outlet water temperature, water losses, the effectiveness, and the second law efficiency were predicted and assessed by statistical indicators such as coefficient of determination (R²), root mean square error (RMSE) and mean absolute percentage error (MAPE). The SVM algorithm had the best predictive accuracy and lowest prediction errors of all the tested models with a value of R2 of 0.985 and RMSE of 1.25 kg/s. Parametric analysis had indicated that the increase in relative humidity between 35% and 92% decreased the evaporation losses by about 55-70% and makeup water demand by about 58-68%. Thermodynamic analysis further revealed that the second-law efficiency improved by approximately 65-75% as the ambient temperature increased. The results indicate that predictive modeling with machine learning offers a useful method in the optimization of cooling tower operation and minimizing water use in industrial systems.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-07-02
DOI
https://doi.org/10.1371/journal.pone.0351944
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Data-driven prediction and thermodynamic performance assessment of industrial cooling towers using advanced machine learning algorithms

Adeel Shehzad, M.A. Mujtaba, Muhammad Nasir Bashir, Yasser Fouad et al.
PLoS ONE
Adsorption and Cooling Systems
article

Data-driven prediction and thermodynamic performance assessment of industrial cooling towers using advanced machine learning algorithms

Adeel Shehzad, M.A. Mujtaba, Muhammad Nasir Bashir, Yasser Fouad, Muhammad Usman, Jana Petrů, Hafiz Muhammad Musharaf, Syed Rehman Jamil, Muhammad Wajid Saleem, Omama Zainab Qaisrani
article en

Abstract

Cooling towers are an important part of the thermal system in industries, where they are used to remove unwanted heat and help maintain the proper performance of the machines. Four machine learning algorithms, namely random forest, support vector machine (SVM), decision tree, and AdaBoost are proposed in this paper for the performance forecasting of cooling towers. for the performance forecasting of cooling towers. These models were built in Python with the help of the following operational parameters: inlet water temperature (32-41°C), ambient air temperature (14-32°C), and relative humidity (35-92%). All the essential performance measures like outlet water temperature, water losses, the effectiveness, and the second law efficiency were predicted and assessed by statistical indicators such as coefficient of determination (R²), root mean square error (RMSE) and mean absolute percentage error (MAPE). The SVM algorithm had the best predictive accuracy and lowest prediction errors of all the tested models with a value of R2 of 0.985 and RMSE of 1.25 kg/s. Parametric analysis had indicated that the increase in relative humidity between 35% and 92% decreased the evaporation losses by about 55-70% and makeup water demand by about 58-68%. Thermodynamic analysis further revealed that the second-law efficiency improved by approximately 65-75% as the ambient temperature increased. The results indicate that predictive modeling with machine learning offers a useful method in the optimization of cooling tower operation and minimizing water use in industrial systems.

PLoS ONEVol. 21(7)
Griffith University (AU), VSB - Technical University of Ostrava (CZ), University of Engineering and Technology Lahore (PK), Gulf University for Science & Technology (KW), Yonsei University (KR), King Saud University (SA)
European Commission, King Saud University
Openalex Percentile: Top 14%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.