Experimental Study on the Seismic Performance of Assembled Shear Walls Based on UHPC Connections

This paper investigates the seismic performance of precast concrete shear-wall subassemblies connected by post-cast ultra-high performance concrete (UHPC) zones and short lap-spliced reinforcement with a lap length of 10d, where d denotes the diameter of the reinforcement bar. Seven quasi-static cyclic tests were conducted, including one cast-in-place control specimen, five specimens with horizontal UHPC back-cast joints at the wall base, and one exploratory specimen with both horizontal and vertical UHPC back-cast joints. The variables considered were the joint arrangement and the axial compression ratio. The specimens with horizontal joints generally exhibited compression-flexure-dominated damage, and the crushing zone shifted from the wall-footing interface to the ordinary concrete immediately above the UHPC back-cast zone. The specimen with the vertical joint (TW6) exhibited bending-shear damage, accompanied by limited in-plane lateral slip at the beam–wall joint and shear damage of several vertical bars. Specimen TW2, with an axial compression ratio of 0.30, was identified as a construction-quality-sensitive case because an insufficient local UHPC cover caused splitting damage and reduced hysteretic stability. The strain measurements indicate that, within the limits of the present instrumentation, the 10d lap in the UHPC zone provided effective stress transfer in the tested specimens; however, direct interface-slip and bond-slip tests are still required for generalized design verification. Under an axial compression ratio of 0.20, TW1 and TW6 showed comparable seismic indices to the cast-in-place specimen, but the conclusions are limited to the tested configurations. All specimens reached ultimate drift ratios greater than 1/100, and their seismic performance is discussed together with failure mode, stiffness degradation, energy dissipation, and connection reliability.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-07-02
DOI
https://doi.org/10.3390/buildings16132644
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on the Seismic Performance of Assembled Shear Walls Based on UHPC Connections

Hui Li, G D Chen, Libo Long, Qizhen Zheng et al.
Buildings
Structural Behavior of Reinforced Concrete
article

Experimental Study on the Seismic Performance of Assembled Shear Walls Based on UHPC Connections

Hui Li, G D Chen, Libo Long, Qizhen Zheng, Decai Nong, Shiwei Yuan
article en

Abstract

This paper investigates the seismic performance of precast concrete shear-wall subassemblies connected by post-cast ultra-high performance concrete (UHPC) zones and short lap-spliced reinforcement with a lap length of 10d, where d denotes the diameter of the reinforcement bar. Seven quasi-static cyclic tests were conducted, including one cast-in-place control specimen, five specimens with horizontal UHPC back-cast joints at the wall base, and one exploratory specimen with both horizontal and vertical UHPC back-cast joints. The variables considered were the joint arrangement and the axial compression ratio. The specimens with horizontal joints generally exhibited compression-flexure-dominated damage, and the crushing zone shifted from the wall-footing interface to the ordinary concrete immediately above the UHPC back-cast zone. The specimen with the vertical joint (TW6) exhibited bending-shear damage, accompanied by limited in-plane lateral slip at the beam–wall joint and shear damage of several vertical bars. Specimen TW2, with an axial compression ratio of 0.30, was identified as a construction-quality-sensitive case because an insufficient local UHPC cover caused splitting damage and reduced hysteretic stability. The strain measurements indicate that, within the limits of the present instrumentation, the 10d lap in the UHPC zone provided effective stress transfer in the tested specimens; however, direct interface-slip and bond-slip tests are still required for generalized design verification. Under an axial compression ratio of 0.20, TW1 and TW6 showed comparable seismic indices to the cast-in-place specimen, but the conclusions are limited to the tested configurations. All specimens reached ultimate drift ratios greater than 1/100, and their seismic performance is discussed together with failure mode, stiffness degradation, energy dissipation, and connection reliability.

BuildingsVol. 16(13)
University of Shanghai for Science and Technology (CN), Shanghai Construction Group (China) (CN)
National Natural Science Foundation of China
Sustainable cities and communities
Openalex Percentile: Top 10%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.