Tau20-RETROmapping System Identifies Driver-Like Activation Patterns in Real-Time During Persistent Atrial Fibrillation
BACKGROUND: Conventional activation mapping of atrial fibrillation (AF) during clinical procedures is limited by low-amplitude, fractionated electrograms and cycle length variability. The Tau20-RETROmapping stimulator-recorder system (TauRhythm Therapies, United Kingdom) is an investigational device used to identify nonpulmonary vein AF drivers by real-time, high-density activation mapping of uniform wavefronts during AF. We validated the accuracy of the system and applied it to left atrial mapping for evidence of AF drivers. METHODS: Left atrial geometry was acquired using a 3-dimensional electroanatomic mapping system with high-density mapping catheters (CARTO 3 with Optrell, or EnSite X with HD Grid). Electrograms were recorded for 30 seconds at multiple left atrial sites. The Tau20-RETROmapping system generates activation maps of organized wavefronts. System performance was manually validated against randomly sampled local electrograms using a grid sweep of thresholds to identify Pareto-optimal parameters in sinus rhythm, atrial pacing, atrial tachycardia (AT), and AF. The system was then applied to identify putative driver activation patterns during persistent AF. RESULTS: We studied 24 patients undergoing pulmonary vein isolation for AF. Six patients presented in sinus rhythm or AT, in whom the system demonstrated a sensitivity of 100.0% (95% CI, 80.5%-100.0%) and a specificity of 100.0% (85.2%-100.0%). Eighteen patients were mapped in AF: the system had a sensitivity of 94.4% (86.2%-98.4%) and a specificity of 97.1% (89.9%-99.6%) when identifying organized AF wavefronts, and accurately identified the earliest activation in 89.6% (79.7%-95.7%) of waves. Stable propagation originating from the left atrial appendage (LAA) was observed in 3/18 patients, while 8/18 demonstrated competing propagation toward and away from the LAA. Conduction away from the LAA was detected along the anterior (8/18 patients), lateral (8/18 patients), and posterior (7/18 patients) walls. No propagation near the LAA was observed in 6/18 patients. CONCLUSIONS: The Tau20-RETROmapping system enables real-time activation mapping of AF, with the most convincing driver-like areas being identified around the LAA.
Authors
- Ji‐Jian Chow (ORCID: https://orcid.org/0000-0003-2454-7644)
- Prapa Kanagaratnam (ORCID: https://orcid.org/0000-0003-3593-2185)
- Nick Linton (ORCID: https://orcid.org/0000-0002-5712-849X)
- Tina Baykaner (ORCID: https://orcid.org/0000-0002-0476-2972)
- Simos Koutsoftidis (ORCID: https://orcid.org/0000-0002-6580-6932)
- Ahran Arnold (ORCID: https://orcid.org/0000-0002-7597-0170)
- Oliver Jones
- Ali Anıl Demirçalı (ORCID: https://orcid.org/0000-0002-3545-3654)
- Emmanuel M. Drakakis (ORCID: https://orcid.org/0000-0001-6649-0573)
- Ivin Jose
- Daniel Keene (ORCID: https://orcid.org/0000-0001-7472-7358)
- Zachary I. Whinnett (ORCID: https://orcid.org/0000-0002-2775-5126)
- Fu Siong Ng (ORCID: https://orcid.org/0000-0002-8681-4368)
- Thorsten Lewalter (ORCID: https://orcid.org/0000-0002-4056-6696)
- Phang Boon Lim (ORCID: https://orcid.org/0000-0003-4888-0070)
- Burak Temelkuran (ORCID: https://orcid.org/0000-0003-2390-5091)
- Nicholas S. Peters (ORCID: https://orcid.org/0000-0002-3581-8078)
- Qindong Zheng
- Huiyi Wu (ORCID: https://orcid.org/0000-0002-1809-9729)
- Junaid Zaman
- Louisa Malcolme-Lawes
- Fergus Heaney
- Jamie Kay
- Norman Qureshi
- Stewart Bissett (ORCID: https://orcid.org/0009-0000-2575-2047)
- Michael Koa-Wing (ORCID: https://orcid.org/0009-0003-7571-4358)
Institutions
- University of Southern California (US)
- Imperial College Healthcare NHS Trust (GB)
- LMU Klinikum (DE)
- Anna Needs Neuroblastoma Answers (US)
- DMA Health Strategies (US)
- Stanford University (US)
Publication Details
- Journal
- Circulation Arrhythmia and Electrophysiology
- Published
- 2026-07-02
- DOI
- https://doi.org/10.1161/circep.126.015039
- Primary Topic
- Atrial Fibrillation Management and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00