Mapping residual chlorine in water supply network of Babile Town in East Hararge Zone of Oromia Regional State using WaterGEMS

Chlorine concentration in water supply distribution network is vital for controlling the health and growth of pathogen organisms at the supply nodes for the users of the distribution system. This study was focused on the evaluation of the hydraulic effect on residual chlorine in the water distribution network of Babile town using waterGEMS integrated arcmap software. Three water pipe system pressure junctions were measured systematically for model calibration purposes, and the results showed that R 2 = 0.9993 linear dependence for field and simulation data The nodal pressure result showed that the optimal 62% was below the minimum requirement of 30% and above the maximum criteria of 8% for the peak demand period.. At a low consumption period, it satisfied 69% and was above the maximum guideline of 31% of junction pressure for pipe network system. According to the results of the velocity computation, 32% and 11% of the water pipes, respectively, were kept up to the hydraulic design standard during periods of high and low use. In a similar vein, certain water pipes had velocities of 58% and 89%, which were below the minimum suggested velocity principle. The simulation result indicated that 47% and 21% of of water pipe comprised optimal residual chlorine for peak and low water demand times. At the same period, about 53% and 79% of water pipes contained residual chlorine that did not meet the WHO standard. The model velocity had a direct effect on the residual chlorine in the water pipe network system. In this case, it is important to raise the chlorine dosage water application and revise the designed network system for sustainable water service, indentify residual chlorine level for home water.

Authors

Institutions

Publication Details

Journal
PLOS Water
Published
2026-07-02
DOI
https://doi.org/10.1371/journal.pwat.0000288
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mapping residual chlorine in water supply network of Babile Town in East Hararge Zone of Oromia Regional State using WaterGEMS

Yohannes Seifu Berego, Mihret Dananto Ulsido, Kenenisa Alemu
PLOS Water
Water Systems and Optimization
article

Mapping residual chlorine in water supply network of Babile Town in East Hararge Zone of Oromia Regional State using WaterGEMS

Yohannes Seifu Berego, Mihret Dananto Ulsido, Kenenisa Alemu
article en

Abstract

Chlorine concentration in water supply distribution network is vital for controlling the health and growth of pathogen organisms at the supply nodes for the users of the distribution system. This study was focused on the evaluation of the hydraulic effect on residual chlorine in the water distribution network of Babile town using waterGEMS integrated arcmap software. Three water pipe system pressure junctions were measured systematically for model calibration purposes, and the results showed that R 2 = 0.9993 linear dependence for field and simulation data The nodal pressure result showed that the optimal 62% was below the minimum requirement of 30% and above the maximum criteria of 8% for the peak demand period.. At a low consumption period, it satisfied 69% and was above the maximum guideline of 31% of junction pressure for pipe network system. According to the results of the velocity computation, 32% and 11% of the water pipes, respectively, were kept up to the hydraulic design standard during periods of high and low use. In a similar vein, certain water pipes had velocities of 58% and 89%, which were below the minimum suggested velocity principle. The simulation result indicated that 47% and 21% of of water pipe comprised optimal residual chlorine for peak and low water demand times. At the same period, about 53% and 79% of water pipes contained residual chlorine that did not meet the WHO standard. The model velocity had a direct effect on the residual chlorine in the water pipe network system. In this case, it is important to raise the chlorine dosage water application and revise the designed network system for sustainable water service, indentify residual chlorine level for home water.

PLOS WaterVol. 5(7)
Haramaya University (ET), Hawassa University (ET)
Openalex Percentile: Top 12%
Water Systems and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.