Tendon safety profiles of fragment-specific fixations of the distal radius extending beyond the watershed line

Introduction: The treatment of complex intra-articular fractures of the distal radius may require the use of ‘fragment specific’ plates potentially irritating the flexor tendons. Our hypothesis is that there may be different rates of tendon irritation depending on the level of projection (radial and/or ulnar) of the plate at the watershed line. We report our experience with a cohort of 113 patients comparing four different plates. Methods: We conducted a single-centre study with prospective inclusion of patients with distal radial fractures from May 2022 to March 2025. The primary objective was to evaluate the rate of tendon irritation according to the type of specific fixation used for intra-articular fractures. At the 6 month visit, an ultrasound was performed to assess the presence or absence of tendon irritation, along with a computed tomography scan to evaluate proper application of the plate to the bone. Results: Forty-two ulnar hook plates (Medartis and Newclip Technics), 31 extradistal plates (Newclip Technics), 21 adjustable anterior rim plates (Medartis) and 19 curved ‘babyfoot’ plates (Medartis) placed distal to the watershed line were used for the fixations. At 6 months, ultrasound revealed tendon irritation in nine cases involving hook plates, 15 involving extradistal plates, 10 involving babyfoot plates and none involving adjustable anterior rim plates. There was a significant difference in the frequency of tendon irritation between plate types ( p < 0.001). Conclusion: Our results suggest that specific, ulnar side fixation, ideally with an adjustable plate, may significantly reduce the risk of tendon irritation after complex distal radial articular fractures. Level of evidence: III

Authors

Institutions

Publication Details

Journal
Journal of Hand Surgery (European Volume)
Published
2026-07-01
DOI
https://doi.org/10.1177/17531934261461998
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tendon safety profiles of fragment-specific fixations of the distal radius extending beyond the watershed line

Rémy Dubian, Jean-Baptiste de Villeneuve Bargemon, Najib Kachouh, Camille Brenac et al.
Journal of Hand Surgery (European Volume)
Orthopedic Surgery and Rehabilitation
article

Tendon safety profiles of fragment-specific fixations of the distal radius extending beyond the watershed line

Rémy Dubian, Jean-Baptiste de Villeneuve Bargemon, Najib Kachouh, Camille Brenac, Emma Abecidan, Lucas Audiffret
article en

Abstract

Introduction: The treatment of complex intra-articular fractures of the distal radius may require the use of ‘fragment specific’ plates potentially irritating the flexor tendons. Our hypothesis is that there may be different rates of tendon irritation depending on the level of projection (radial and/or ulnar) of the plate at the watershed line. We report our experience with a cohort of 113 patients comparing four different plates. Methods: We conducted a single-centre study with prospective inclusion of patients with distal radial fractures from May 2022 to March 2025. The primary objective was to evaluate the rate of tendon irritation according to the type of specific fixation used for intra-articular fractures. At the 6 month visit, an ultrasound was performed to assess the presence or absence of tendon irritation, along with a computed tomography scan to evaluate proper application of the plate to the bone. Results: Forty-two ulnar hook plates (Medartis and Newclip Technics), 31 extradistal plates (Newclip Technics), 21 adjustable anterior rim plates (Medartis) and 19 curved ‘babyfoot’ plates (Medartis) placed distal to the watershed line were used for the fixations. At 6 months, ultrasound revealed tendon irritation in nine cases involving hook plates, 15 involving extradistal plates, 10 involving babyfoot plates and none involving adjustable anterior rim plates. There was a significant difference in the frequency of tendon irritation between plate types ( p < 0.001). Conclusion: Our results suggest that specific, ulnar side fixation, ideally with an adjustable plate, may significantly reduce the risk of tendon irritation after complex distal radial articular fractures. Level of evidence: III

Journal of Hand Surgery (European Volume)
Aix-Marseille Université (FR), Hôpital Sainte-Marguerite (FR), Centre Pompidou (FR)
Life in Land
Openalex Percentile: Top 6%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.