Effects of robotic pelvic guidance and visual feedback designs on upper body seated coordination and sense of agency in virtual reality

Trunk impairment from neurological conditions such as spinal cord injury, cerebral palsy, and stroke limits postural coordination and functional independence. Sense of agency (SoA), the perceived control over one’s movements, influences motor learning and rehabilitation engagement, yet has not been examined in seated postural training. This study investigates how robotic pelvic guidance and visual feedback (VF) designs influence motor coordination and SoA during a seated reaching task in virtual reality (VR), validated here with able-bodied subjects. Thirty-two healthy adults were randomly assigned to four groups ( n = 8) in a 2 × 2 between-subjects design: pelvic guidance (guided vs unguided) and VF type (control VF, CVF: a pursuit-tracking moving target, vs error-based VF, EVF: displaying only the hand–target error). In the guided condition, the pelvic Wheelchair Robot for Active Postural Support (pWRAPS) actively guided pelvic orientation during a four-direction hand-tracking game. In the unguided condition, the robot operated in transparent mode. Participants receiving pelvic guidance showed significantly greater improvements in task performance and pelvis–trunk–hand coordination than unguided participants, regardless of VF type. EVF influenced trunk–pelvis coordination independently of guidance, with CVF yielding greater trunk–pelvis improvement. Trunk–pelvis coordination emerged as the strongest predictor of SoA, and SoA increased significantly at post-test, suggesting that perceived agency reflects coordination quality rather than the presence or absence of robotic assistance. Critically, guidance improved coordination without diminishing SoA, indicating compatible biomechanical and psychological rehabilitation goals. These findings support integrating robotic pelvic guidance with VR-based feedback for seated postural rehabilitation.

Authors

Institutions

Publication Details

Journal
The International Journal of Robotics Research
Published
2026-07-02
DOI
https://doi.org/10.1177/02783649261461646
Primary Topic
Free Will and Agency
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of robotic pelvic guidance and visual feedback designs on upper body seated coordination and sense of agency in virtual reality

Victor Santamaria, Sunil Kumar Agrawal, Chawin Ophaswongse, Victoria Lent
The International Journal of Robotics Research
Free Will and Agency
article

Effects of robotic pelvic guidance and visual feedback designs on upper body seated coordination and sense of agency in virtual reality

Victor Santamaria, Sunil Kumar Agrawal, Chawin Ophaswongse, Victoria Lent
article en

Abstract

Trunk impairment from neurological conditions such as spinal cord injury, cerebral palsy, and stroke limits postural coordination and functional independence. Sense of agency (SoA), the perceived control over one’s movements, influences motor learning and rehabilitation engagement, yet has not been examined in seated postural training. This study investigates how robotic pelvic guidance and visual feedback (VF) designs influence motor coordination and SoA during a seated reaching task in virtual reality (VR), validated here with able-bodied subjects. Thirty-two healthy adults were randomly assigned to four groups ( n = 8) in a 2 × 2 between-subjects design: pelvic guidance (guided vs unguided) and VF type (control VF, CVF: a pursuit-tracking moving target, vs error-based VF, EVF: displaying only the hand–target error). In the guided condition, the pelvic Wheelchair Robot for Active Postural Support (pWRAPS) actively guided pelvic orientation during a four-direction hand-tracking game. In the unguided condition, the robot operated in transparent mode. Participants receiving pelvic guidance showed significantly greater improvements in task performance and pelvis–trunk–hand coordination than unguided participants, regardless of VF type. EVF influenced trunk–pelvis coordination independently of guidance, with CVF yielding greater trunk–pelvis improvement. Trunk–pelvis coordination emerged as the strongest predictor of SoA, and SoA increased significantly at post-test, suggesting that perceived agency reflects coordination quality rather than the presence or absence of robotic assistance. Critically, guidance improved coordination without diminishing SoA, indicating compatible biomechanical and psychological rehabilitation goals. These findings support integrating robotic pelvic guidance with VR-based feedback for seated postural rehabilitation.

The International Journal of Robotics Research
Chulalongkorn University (TH), New York Medical College (US), Spinal Cord Injury Ontario (CA), Helen Hayes Hospital (US), Spinal Injuries Center (JP), Columbia University (US)
New York State Department of Health
Openalex Percentile: Top 7%
Free Will and Agency
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.