Frequency Control Capability Estimation for Renewable Energy Stations Accounting for Dynamic Response Variations and Power Decoupling

The large-scale integration of converter-interfaced renewable energy sources has significantly reduced power system inertia, posing challenges to frequency stability. Although virtual inertia and primary frequency control can enhance the frequency support capability of renewable energy units, their actual performance often deviates from set values due to dynamic response differences among various energy sources (e.g., energy storage, photovoltaic, and wind power) and coupling between inertia and primary regulation power. Existing evaluation methods fail to accurately decouple these components or account for unit-specific dynamic characteristics, leading to considerable estimation errors. To address these issues, this paper proposes a novel estimation method for the frequency regulation capability of renewable energy stations. First, the dynamic frequency response characteristics of synchronous and renewable generators are compared. Then, a decoupling method is developed to separate virtual inertia power from primary frequency regulation power by leveraging their distinct response features. A first-order plus delay time (FOPDT) model is employed to characterize the external frequency response of different renewable energy units. The primary frequency regulation coefficient is estimated using a sliding window integration method, and the virtual inertia time constant is identified via a gradient descent algorithm based on the decoupled inertia power. A hardware-in-the-loop experimental platform is constructed using a real-time digital simulator (RTDS) and phasor measurement units (PMUs) to validate the proposed method. Simulation results show that the estimation errors for energy storage, photovoltaic, and wind power units are 0.63%, 6.38%, and 8.38% for the virtual inertia time constant and 0.45%, 0.72%, and 3.81% for the primary frequency regulation coefficient, respectively. Field test data further confirm the practical applicability and accuracy of the approach. The proposed method enables precise frequency control capability estimation, providing a reliable basis for parameter setting and capacity configuration of frequency regulation resources in low-inertia power systems.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2026-07-02
DOI
https://doi.org/10.3390/eng7070323
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency Control Capability Estimation for Renewable Energy Stations Accounting for Dynamic Response Variations and Power Decoupling

J M Li, Zhihui Tong, Weishang Meng, Xu Jing et al.
Eng—Advances in Engineering
Wind Turbine Control Systems
article

Frequency Control Capability Estimation for Renewable Energy Stations Accounting for Dynamic Response Variations and Power Decoupling

J M Li, Zhihui Tong, Weishang Meng, Xu Jing, Zhirong Li
article en

Abstract

The large-scale integration of converter-interfaced renewable energy sources has significantly reduced power system inertia, posing challenges to frequency stability. Although virtual inertia and primary frequency control can enhance the frequency support capability of renewable energy units, their actual performance often deviates from set values due to dynamic response differences among various energy sources (e.g., energy storage, photovoltaic, and wind power) and coupling between inertia and primary regulation power. Existing evaluation methods fail to accurately decouple these components or account for unit-specific dynamic characteristics, leading to considerable estimation errors. To address these issues, this paper proposes a novel estimation method for the frequency regulation capability of renewable energy stations. First, the dynamic frequency response characteristics of synchronous and renewable generators are compared. Then, a decoupling method is developed to separate virtual inertia power from primary frequency regulation power by leveraging their distinct response features. A first-order plus delay time (FOPDT) model is employed to characterize the external frequency response of different renewable energy units. The primary frequency regulation coefficient is estimated using a sliding window integration method, and the virtual inertia time constant is identified via a gradient descent algorithm based on the decoupled inertia power. A hardware-in-the-loop experimental platform is constructed using a real-time digital simulator (RTDS) and phasor measurement units (PMUs) to validate the proposed method. Simulation results show that the estimation errors for energy storage, photovoltaic, and wind power units are 0.63%, 6.38%, and 8.38% for the virtual inertia time constant and 0.45%, 0.72%, and 3.81% for the primary frequency regulation coefficient, respectively. Field test data further confirm the practical applicability and accuracy of the approach. The proposed method enables precise frequency control capability estimation, providing a reliable basis for parameter setting and capacity configuration of frequency regulation resources in low-inertia power systems.

Eng—Advances in EngineeringVol. 7(7)
North University of China (CN)
Natural Science Foundation of Inner Mongolia
Affordable and clean energy
Openalex Percentile: Top 12%
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.