Study on Defect Characterization Parameters of Anode Saturable Reactors for HVDC Converter Valves

To address the issues of temperature rise accumulation, structural vibration, and air gap degradation that occur during the long-term operation of Anode Saturable Reactors used in high-voltage direct-current (HVDC) converter valves, electromagnetic-structural and electromagnetic-thermal multi-physics coupling analysis models were established using COMSOL Multiphysics software. The monitorable quantities capable of characterizing defects in Anode Saturable Reactors were systematically investigated from three aspects: vibration signals, thermal signals, and electrical signals. First, a one-way electromagnetic-structural coupling vibration model was established to analyze the vibration characteristics under normal operation, loose core conditions, and polyurethane hardening conditions. Second, an electromagnetic-thermal coupling model was established to compare the core loss and temperature rise distribution between the defect-free condition and the condition with reduced air gap defects. Finally, the effects of air gap reduction on electrical parameters such as unsaturated inductance and frequency sweep impedance were analyzed. The results indicate that the dual-peak characteristics and residual vibration of vibration signals can reflect the looseness of the iron core, while thermal aging of the polyurethane filling material further weakens the system’s damping capacity, intensifying vibration impact on the core and structural components. A reduction in air gap leads to an increase in local core loss of approximately 47.9%, giving rise to local hot spots. For the shell-type ASR investigated in this study, the temperature rise of the reactor casing remains almost unchanged. The unsaturated inductance and the impedance value near 10 kHz are highly sensitive to air gap variations and can serve as effective feature quantities for online monitoring.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-07-01
DOI
https://doi.org/10.3390/en19133132
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Defect Characterization Parameters of Anode Saturable Reactors for HVDC Converter Valves

Donglin Xu, Lei Pang, Yingfeng Zhu, Xuebin Lv et al.
Energies
HVDC Systems and Fault Protection
article

Study on Defect Characterization Parameters of Anode Saturable Reactors for HVDC Converter Valves

Donglin Xu, Lei Pang, Yingfeng Zhu, Xuebin Lv, Chenhao Li, Andong Wang, Ming Li, Ruijia Liu
article en

Abstract

To address the issues of temperature rise accumulation, structural vibration, and air gap degradation that occur during the long-term operation of Anode Saturable Reactors used in high-voltage direct-current (HVDC) converter valves, electromagnetic-structural and electromagnetic-thermal multi-physics coupling analysis models were established using COMSOL Multiphysics software. The monitorable quantities capable of characterizing defects in Anode Saturable Reactors were systematically investigated from three aspects: vibration signals, thermal signals, and electrical signals. First, a one-way electromagnetic-structural coupling vibration model was established to analyze the vibration characteristics under normal operation, loose core conditions, and polyurethane hardening conditions. Second, an electromagnetic-thermal coupling model was established to compare the core loss and temperature rise distribution between the defect-free condition and the condition with reduced air gap defects. Finally, the effects of air gap reduction on electrical parameters such as unsaturated inductance and frequency sweep impedance were analyzed. The results indicate that the dual-peak characteristics and residual vibration of vibration signals can reflect the looseness of the iron core, while thermal aging of the polyurethane filling material further weakens the system’s damping capacity, intensifying vibration impact on the core and structural components. A reduction in air gap leads to an increase in local core loss of approximately 47.9%, giving rise to local hot spots. For the shell-type ASR investigated in this study, the temperature rise of the reactor casing remains almost unchanged. The unsaturated inductance and the impedance value near 10 kHz are highly sensitive to air gap variations and can serve as effective feature quantities for online monitoring.

EnergiesVol. 19(13)
China Power Engineering Consulting Group (China) (CN), Xi'an Jiaotong University (CN)
State Grid Shandong Electric Power Company
Affordable and clean energy
Openalex Percentile: Top 12%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.