Research on the Range Extension Method of GM Counter Based on Time-to-Count

The Geiger–Müller (GM) counter is widely used in γ dose rate measurement, but its long dead time limits its range. To extend the upper limit of the GM counter’s range and expand its application scope, this paper validates the Time-to-Count method with a J306 gamma GM counter. The hardware and software structure of the radiation measurement system is designed according to the basic principle of measuring radiation intensity, using the Time-to-Count method. Experiments show that the Time-to-Count method has higher linearity than the traditional pulse-counting method, and the upper limit of the range is extended by two orders of magnitude.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-07-01
DOI
https://doi.org/10.3390/app16136547
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Range Extension Method of GM Counter Based on Time-to-Count

Xinfeng Fan, Peng Xu, Yi-Xiang Wang, Jialin Chen et al.
Applied Sciences
Radiation Detection and Scintillator Technologies
article

Research on the Range Extension Method of GM Counter Based on Time-to-Count

Xinfeng Fan, Peng Xu, Yi-Xiang Wang, Jialin Chen, Qingxu Yao
article en

Abstract

The Geiger–Müller (GM) counter is widely used in γ dose rate measurement, but its long dead time limits its range. To extend the upper limit of the GM counter’s range and expand its application scope, this paper validates the Time-to-Count method with a J306 gamma GM counter. The hardware and software structure of the radiation measurement system is designed according to the basic principle of measuring radiation intensity, using the Time-to-Count method. Experiments show that the Time-to-Count method has higher linearity than the traditional pulse-counting method, and the upper limit of the range is extended by two orders of magnitude.

Applied SciencesVol. 16(13)
PLA Rocket Force University of Engineering (CN)
Openalex Percentile: Top 8%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.