A Biomechanical Proof‐of‐Concept Study of Scaffold‐Augmented Distraction Osteogenesis Using 3D‐Printed Hyperelastic Bone™ in a Rabbit Tibial Lengthening Model

Distraction osteogenesis (DO) for limb lengthening often requires prolonged fixation while the regenerate consolidates. Adjuncts that improve the regenerate quality could reduce morbidity and treatment time. Hyperelastic Bone™ (HEB) is a 3D-printed hydroxyapatite (HA)/polylactic-co-glycolic acid (PLGA) scaffold, but its efficacy as an osteotomy-site adjunct during DO is unclear. After IACUC approval, rabbits underwent left tibial lengthening with a mini-rail external fixator distracted at 0.75 mm/day to 20% tibial length and received no scaffold (control), traditional Hyperelastic Bone™ (10% PLGA/90% HA), or a biphasic formulation (10% PLGA/70% HA/20% β-tricalcium phosphate [β-TCP]) placed subperiosteally at the osteotomy site. The contralateral tibiae served as references. After 8 weeks of consolidation, radiographs, micro-CT (prespecified endpoint: regenerate BMD), and torsional testing (prespecified endpoint: stiffness) were performed. Fourteen rabbits underwent attempted lengthening. Intraoperative fractures (n = 2) and fixation loss (n = 3) reduced complete terminal datasets to nine, all of which completed micro-CT and torsion testing. Radiographs confirmed regenerate formation. Regenerate BMD remained below contralateral values with controls being intermediate to the traditional and biphasic HEB formulations (60.5%, 63.8%, and 54.7% of contralateral, respectively). Despite no mineral density improvement, scaffold-treated regenerate demonstrated higher torsional stiffness and strength metrics, greatest with the biphasic formulation, with lower failure displacement and higher polar moment of inertia. Statement of Clinical Significance: A scaffold that improves functional regenerate performance could enable earlier safer weight bearing and device removal and reduce nonunion/refracture risk in DO.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2026-07-01
DOI
https://doi.org/10.1002/jor.70244
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Biomechanical Proof‐of‐Concept Study of Scaffold‐Augmented Distraction Osteogenesis Using 3D‐Printed Hyperelastic Bone™ in a Rabbit Tibial Lengthening Model

Daryn Strub, Anirejuoritse Bafor, Christopher Iobst, Sara McBride‐Gagyi et al.
Journal of Orthopaedic Research®
Bone fractures and treatments
article

A Biomechanical Proof‐of‐Concept Study of Scaffold‐Augmented Distraction Osteogenesis Using 3D‐Printed Hyperelastic Bone™ in a Rabbit Tibial Lengthening Model

Daryn Strub, Anirejuoritse Bafor, Christopher Iobst, Sara McBride‐Gagyi, Benjamin Brooks
article en

Abstract

Distraction osteogenesis (DO) for limb lengthening often requires prolonged fixation while the regenerate consolidates. Adjuncts that improve the regenerate quality could reduce morbidity and treatment time. Hyperelastic Bone™ (HEB) is a 3D-printed hydroxyapatite (HA)/polylactic-co-glycolic acid (PLGA) scaffold, but its efficacy as an osteotomy-site adjunct during DO is unclear. After IACUC approval, rabbits underwent left tibial lengthening with a mini-rail external fixator distracted at 0.75 mm/day to 20% tibial length and received no scaffold (control), traditional Hyperelastic Bone™ (10% PLGA/90% HA), or a biphasic formulation (10% PLGA/70% HA/20% β-tricalcium phosphate [β-TCP]) placed subperiosteally at the osteotomy site. The contralateral tibiae served as references. After 8 weeks of consolidation, radiographs, micro-CT (prespecified endpoint: regenerate BMD), and torsional testing (prespecified endpoint: stiffness) were performed. Fourteen rabbits underwent attempted lengthening. Intraoperative fractures (n = 2) and fixation loss (n = 3) reduced complete terminal datasets to nine, all of which completed micro-CT and torsion testing. Radiographs confirmed regenerate formation. Regenerate BMD remained below contralateral values with controls being intermediate to the traditional and biphasic HEB formulations (60.5%, 63.8%, and 54.7% of contralateral, respectively). Despite no mineral density improvement, scaffold-treated regenerate demonstrated higher torsional stiffness and strength metrics, greatest with the biphasic formulation, with lower failure displacement and higher polar moment of inertia. Statement of Clinical Significance: A scaffold that improves functional regenerate performance could enable earlier safer weight bearing and device removal and reduce nonunion/refracture risk in DO.

Journal of Orthopaedic Research®Vol. 44(7)
Nationwide Children's Hospital (US), The Ohio State University (US)
Openalex Percentile: Top 7%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.