Transcatheter Closure of Post–Myocardial Infarction Ventricular Septal Rupture Using an Atrial Septal Defect Occluder

OBJECTIVE: To describe the procedural strategy and technical considerations for transcatheter closure of post-myocardial infarction ventricular septal rupture (VSR) using an atrial septal defect (ASD) occluder in a patient unsuitable for surgical repair. KEY STEPS: An elderly, frail patient with postinfarction VSR and cardiogenic shock was stabilized with an intra-aortic balloon pump. Given the high surgical risk, transcatheter closure was performed after a 14-day delay to allow infarcted tissue stabilization. Multimodality imaging was used to assess defect morphology and rim adequacy. An ASD occluder was deployed under echocardiographic guidance, reducing shunt flow and improving hemodynamics. POTENTIAL PITFALLS: Wire entrapment in the tricuspid subvalvular apparatus may cause tricuspid regurgitation. Careful wire manipulation and appropriate snaring techniques are essential. Adequate rim assessment is also critical. TAKE-HOME MESSAGE: Transcatheter VSR closure using an ASD occluder is a feasible alternative in selected inoperable patients, particularly when dedicated VSD devices are unavailable.

Authors

Institutions

Publication Details

Journal
JACC Case Reports
Published
2026-07-01
DOI
https://doi.org/10.1016/j.jaccas.2026.109113
Primary Topic
Cardiac Structural Anomalies and Repair
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transcatheter Closure of Post–Myocardial Infarction Ventricular Septal Rupture Using an Atrial Septal Defect Occluder

Shin Watanabe, Yuta Tsujisaka, Masahide Kawatou, Takahiro Horie et al.
JACC Case Reports
Cardiac Structural Anomalies and Repair
article

Transcatheter Closure of Post–Myocardial Infarction Ventricular Septal Rupture Using an Atrial Septal Defect Occluder

Shin Watanabe, Yuta Tsujisaka, Masahide Kawatou, Takahiro Horie, K Minatoya, Hiromasa Kira, Kanna Nakamura, Norio Tada, Hiroki Shiomi, Koh Ono
article en

Abstract

OBJECTIVE: To describe the procedural strategy and technical considerations for transcatheter closure of post-myocardial infarction ventricular septal rupture (VSR) using an atrial septal defect (ASD) occluder in a patient unsuitable for surgical repair. KEY STEPS: An elderly, frail patient with postinfarction VSR and cardiogenic shock was stabilized with an intra-aortic balloon pump. Given the high surgical risk, transcatheter closure was performed after a 14-day delay to allow infarcted tissue stabilization. Multimodality imaging was used to assess defect morphology and rim adequacy. An ASD occluder was deployed under echocardiographic guidance, reducing shunt flow and improving hemodynamics. POTENTIAL PITFALLS: Wire entrapment in the tricuspid subvalvular apparatus may cause tricuspid regurgitation. Careful wire manipulation and appropriate snaring techniques are essential. Adequate rim assessment is also critical. TAKE-HOME MESSAGE: Transcatheter VSR closure using an ASD occluder is a feasible alternative in selected inoperable patients, particularly when dedicated VSD devices are unavailable.

JACC Case Reports
Kyoto University (JP), Sendai Kousei Hospital (JP)
Good health and well-being
Openalex Percentile: Top 6%
Cardiac Structural Anomalies and Repair
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.