Low-Cost Homemade Simulation Trainer for the Erector Spinae Plane Block

Introduction The ultrasound-guided erector spinae plane block (USG-ESPB) is an interfascial plane block that provides analgesia for several conditions causing truncal pain. Many training models are available for purchase but may be cost-prohibitive for anesthesia and emergency medicine training programs. This article reports on a low-cost, reusable gel thoracic spine phantom for teaching the USG-ESPB. Materials and methods The phantom was made using an Axis Scientific skeleton model modified to include only the thoracic vertebrae, a plastic bin, and Huminic medical gel #0. The spine model was suspended in the bin, and the gel was melted at 275ºF and poured over it. Eight board-certified pain physicians and regional anesthesiologists at a pain management fellowship site were then surveyed to assess the characteristics of the phantom by touch and ultrasound. Results Of the participating physicians, 7/8 (87.5%) agreed or strongly agreed that the phantom reproduced the texture and resistance of human tissue. All participants (8/8, 100%) agreed or strongly agreed that the gel medium provided sufficient ultrasound penetration and enabled them to identify targets within it. All participants (8/8, 100%) also agreed or strongly agreed that the phantom was more transportable than commercial models and cadavers. Additionally, 7/8 (87.5%) agreed or strongly agreed that the phantom was more reproducible than commercial models, while 6/8 (75%) agreed or strongly agreed that it was more reproducible than a cadaver. Conclusions These findings highlight the potential for low-cost gel models to enhance regional anesthesia education. This phantom’s favorable ratings in tissue realism, ultrasound visibility, portability, reproducibility, and reusability, especially when compared to commercial models and cadaver labs, support its value as an educational tool. Similar models may expand access to procedural training without the prohibitive cost of commercial simulators or cadavers.

Authors

Publication Details

Journal
Cureus
Published
2026-07-01
DOI
https://doi.org/10.7759/cureus.111869
Primary Topic
Anesthesia and Pain Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-Cost Homemade Simulation Trainer for the Erector Spinae Plane Block

Benjamin Liotta, Joshua Perese, Jessica Oswald, Philip S Fallah
Cureus
Anesthesia and Pain Management
article

Low-Cost Homemade Simulation Trainer for the Erector Spinae Plane Block

Benjamin Liotta, Joshua Perese, Jessica Oswald, Philip S Fallah
article en

Abstract

Introduction The ultrasound-guided erector spinae plane block (USG-ESPB) is an interfascial plane block that provides analgesia for several conditions causing truncal pain. Many training models are available for purchase but may be cost-prohibitive for anesthesia and emergency medicine training programs. This article reports on a low-cost, reusable gel thoracic spine phantom for teaching the USG-ESPB. Materials and methods The phantom was made using an Axis Scientific skeleton model modified to include only the thoracic vertebrae, a plastic bin, and Huminic medical gel #0. The spine model was suspended in the bin, and the gel was melted at 275ºF and poured over it. Eight board-certified pain physicians and regional anesthesiologists at a pain management fellowship site were then surveyed to assess the characteristics of the phantom by touch and ultrasound. Results Of the participating physicians, 7/8 (87.5%) agreed or strongly agreed that the phantom reproduced the texture and resistance of human tissue. All participants (8/8, 100%) agreed or strongly agreed that the gel medium provided sufficient ultrasound penetration and enabled them to identify targets within it. All participants (8/8, 100%) also agreed or strongly agreed that the phantom was more transportable than commercial models and cadavers. Additionally, 7/8 (87.5%) agreed or strongly agreed that the phantom was more reproducible than commercial models, while 6/8 (75%) agreed or strongly agreed that it was more reproducible than a cadaver. Conclusions These findings highlight the potential for low-cost gel models to enhance regional anesthesia education. This phantom’s favorable ratings in tissue realism, ultrasound visibility, portability, reproducibility, and reusability, especially when compared to commercial models and cadaver labs, support its value as an educational tool. Similar models may expand access to procedural training without the prohibitive cost of commercial simulators or cadavers.

Cureus
Openalex Percentile: Top 6%
Anesthesia and Pain Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Low-Cost Homemade Simulation Trainer for the Erector Spinae Plane Block — Benjamin Liotta, Joshua Perese, et al. · Cureus (2026) | TGRS Research Map | TGRS