Load frequency control of microgrids integrated pump hydro-storage

Because it decouples the secondary frequency controller and alters the dynamics of the Load Frequency Control (LFC) system in turbine and pump operations, hydraulic pumped hydropower is regarded as a serious current problem. To enable the Pump Hydro-storage (PHS) system to function adequately within interconnected resilient microgrids, the stability challenges are addressed. This could potentially cause instability in power systems that use PHS. The proposed solution turns the problem into a Multi-input Multi-output (MIMO) problem by appropriately designing the closed-loop link between the disturbance and the area control error, using an H ∞ -based methodology to develop robust controllers. A two-microgrid system is examined, with the PHS system situated at one of them. This reflects the influence of the PHS turbine in reducing the system’s over- and undershoots. Numerical simulations show that the proposed H ∞ controllers outperform a number of reported controllers in terms of settling times and several performance indices.

Authors

Institutions

Publication Details

Journal
Ain Shams Engineering Journal
Published
2026-07-01
DOI
https://doi.org/10.1016/j.asej.2026.104263
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Load frequency control of microgrids integrated pump hydro-storage

Alaaeldin M. Abdelshafy, Talal Alharbi, Farag K. Abo‐Elyousr
Ain Shams Engineering Journal
Frequency Control in Power Systems
article

Load frequency control of microgrids integrated pump hydro-storage

Alaaeldin M. Abdelshafy, Talal Alharbi, Farag K. Abo‐Elyousr
article en

Abstract

Because it decouples the secondary frequency controller and alters the dynamics of the Load Frequency Control (LFC) system in turbine and pump operations, hydraulic pumped hydropower is regarded as a serious current problem. To enable the Pump Hydro-storage (PHS) system to function adequately within interconnected resilient microgrids, the stability challenges are addressed. This could potentially cause instability in power systems that use PHS. The proposed solution turns the problem into a Multi-input Multi-output (MIMO) problem by appropriately designing the closed-loop link between the disturbance and the area control error, using an H ∞ -based methodology to develop robust controllers. A two-microgrid system is examined, with the PHS system situated at one of them. This reflects the influence of the PHS turbine in reducing the system’s over- and undershoots. Numerical simulations show that the proposed H ∞ controllers outperform a number of reported controllers in terms of settling times and several performance indices.

Ain Shams Engineering JournalVol. 17(9)
Qassim University (SA), Assiut University (EG)
Affordable and clean energy
Openalex Percentile: Top 12%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.