Comprehensive Analytical Framework for Prestressed Steel–Concrete Composite Beams: Verification and Parametric Evaluation

This study develops a comprehensive analytical framework to predict the flexural behavior of externally prestressed steel–concrete composite I-girders (EPCIBs) subjected to positive bending. The analytical model is formulated using strain compatibility and internal force equilibrium and accounts for elastic–plastic behavior of concrete, structural steel, and external tendons. Validation against three independent experimental programs demonstrated strong accuracy, with differences in ultimate moment within 5–8%, mid-span deflection within 6–10%, and tendon stress increments within less than 6% compared with measured results. Additional validation against nonlinear ABAQUS finite element (FE) models confirmed similar accuracy, with ultimate moment discrepancies generally below 8%. A comprehensive parametric study quantified the sensitivity of EPCIB behavior to span length, shear-span ratio, prestressing level, concrete slab properties, and steel-section geometry. Increasing the initial prestressing force from 160 kN to 300 kN increased the ultimate moment capacity by 10–15% and reduced service-level deflection by 18%. Increasing slab thickness from 60 mm to 120 mm enhanced capacity from 230 kN·m to 380 kN·m (a 65% increase), while increasing slab width from 600 mm to 1200 mm produced a moderate 10–12% capacity gain. Enhancing steel section dimensions showed the highest influence: increasing bottom-flange width from 200 mm to 300 mm increased strength by 30–35%, increasing bottom-flange thickness from 8 mm to 14 mm improved capacity by 55–60%, and increasing web depth from 200 mm to 400 mm more than doubled the flexural capacity (up to 150% increase, reaching 780–800 kN·m). Web-thickness variations (4–8 mm) produced smaller gains of 25–30%.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-07-01
DOI
https://doi.org/10.3390/buildings16132632
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive Analytical Framework for Prestressed Steel–Concrete Composite Beams: Verification and Parametric Evaluation

Islam A. Salama, Ayman El‐Zohairy
Buildings
Structural Load-Bearing Analysis
article

Comprehensive Analytical Framework for Prestressed Steel–Concrete Composite Beams: Verification and Parametric Evaluation

Islam A. Salama, Ayman El‐Zohairy
article en

Abstract

This study develops a comprehensive analytical framework to predict the flexural behavior of externally prestressed steel–concrete composite I-girders (EPCIBs) subjected to positive bending. The analytical model is formulated using strain compatibility and internal force equilibrium and accounts for elastic–plastic behavior of concrete, structural steel, and external tendons. Validation against three independent experimental programs demonstrated strong accuracy, with differences in ultimate moment within 5–8%, mid-span deflection within 6–10%, and tendon stress increments within less than 6% compared with measured results. Additional validation against nonlinear ABAQUS finite element (FE) models confirmed similar accuracy, with ultimate moment discrepancies generally below 8%. A comprehensive parametric study quantified the sensitivity of EPCIB behavior to span length, shear-span ratio, prestressing level, concrete slab properties, and steel-section geometry. Increasing the initial prestressing force from 160 kN to 300 kN increased the ultimate moment capacity by 10–15% and reduced service-level deflection by 18%. Increasing slab thickness from 60 mm to 120 mm enhanced capacity from 230 kN·m to 380 kN·m (a 65% increase), while increasing slab width from 600 mm to 1200 mm produced a moderate 10–12% capacity gain. Enhancing steel section dimensions showed the highest influence: increasing bottom-flange width from 200 mm to 300 mm increased strength by 30–35%, increasing bottom-flange thickness from 8 mm to 14 mm improved capacity by 55–60%, and increasing web depth from 200 mm to 400 mm more than doubled the flexural capacity (up to 150% increase, reaching 780–800 kN·m). Web-thickness variations (4–8 mm) produced smaller gains of 25–30%.

BuildingsVol. 16(13)
University of Basrah (IQ), Zagazig University (EG), East Texas A&M University (US), Higher Institute of Engineering (EG), Iraq University College (IQ)
Sustainable cities and communities
Openalex Percentile: Top 12%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.