A Hyperbranched Rolling Circle Amplification Assay Using Aptamer–Hemin/G-Quadruplex Recognition for the Detection of Creatine Kinase-MB

High Resolution Image Download MS PowerPoint Slide Creatine kinase-myocardial band (CK-MB) remains an important biomarker for the early diagnosis and clinical management of myocardial infarction. Here, we report a sensitive colorimetric assay for CK-MB based on a conformation-locked aptamer guanine-quadruplex (G-quadruplex) system integrated with magnetic nanoparticle capture and hyperbranched rolling circle amplification (HRCA). Target binding induces conformational unlocking of the aptamer, initiating HRCA-mediated signal amplification and generating a concentration-dependent colorimetric response in the presence of a chromogenic substrate. A compact 3D-printed imaging module, combined with a Python-based processing pipeline, was used to extract grayscale intensity values from assay images for quantitative analysis. Using only 25 μL of sample, the assay achieved limits of detection (LOD) of 0.268 ng/mL in aqueous samples and 0.328 ng/mL in blood-spiked samples, and limits of quantification (LOQ) of 0.89 ng/mL and 1.09 ng/mL, respectively, with a linear dynamic range of 0.5–100 ng/mL. Grayscale intensity was inversely proportional to CK-MB concentration, enabling quantitative detection across clinically relevant levels. The HRCA amplification process and target-induced activation were further validated by TapeStation gel electrophoresis, confirming the formation of amplified DNA nanostructures. This platform provides a low-volume, amplification-based strategy for CK-MB detection that is compatible with simple optical readout and has strong potential for point-of-care applications.

Authors

Institutions

Publication Details

Journal
ACS Measurement Science Au
Published
2026-06-30
DOI
https://doi.org/10.1021/acsmeasuresciau.6c00016
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Hyperbranched Rolling Circle Amplification Assay Using Aptamer–Hemin/G-Quadruplex Recognition for the Detection of Creatine Kinase-MB

Ensiyeh Mirsadoughi, Gerard L. Coté, Fatemeh Zare, Sayantan Tripathy et al.
ACS Measurement Science Au
Advanced biosensing and bioanalysis techniques
article

A Hyperbranched Rolling Circle Amplification Assay Using Aptamer–Hemin/G-Quadruplex Recognition for the Detection of Creatine Kinase-MB

Ensiyeh Mirsadoughi, Gerard L. Coté, Fatemeh Zare, Sayantan Tripathy, Samuel Mabbott
article en

Abstract

High Resolution Image Download MS PowerPoint Slide Creatine kinase-myocardial band (CK-MB) remains an important biomarker for the early diagnosis and clinical management of myocardial infarction. Here, we report a sensitive colorimetric assay for CK-MB based on a conformation-locked aptamer guanine-quadruplex (G-quadruplex) system integrated with magnetic nanoparticle capture and hyperbranched rolling circle amplification (HRCA). Target binding induces conformational unlocking of the aptamer, initiating HRCA-mediated signal amplification and generating a concentration-dependent colorimetric response in the presence of a chromogenic substrate. A compact 3D-printed imaging module, combined with a Python-based processing pipeline, was used to extract grayscale intensity values from assay images for quantitative analysis. Using only 25 μL of sample, the assay achieved limits of detection (LOD) of 0.268 ng/mL in aqueous samples and 0.328 ng/mL in blood-spiked samples, and limits of quantification (LOQ) of 0.89 ng/mL and 1.09 ng/mL, respectively, with a linear dynamic range of 0.5–100 ng/mL. Grayscale intensity was inversely proportional to CK-MB concentration, enabling quantitative detection across clinically relevant levels. The HRCA amplification process and target-induced activation were further validated by TapeStation gel electrophoresis, confirming the formation of amplified DNA nanostructures. This platform provides a low-volume, amplification-based strategy for CK-MB detection that is compatible with simple optical readout and has strong potential for point-of-care applications.

ACS Measurement Science Au
Mitchell Institute (US), Texas A&M Engineering Experiment Station, Texas A&M University (US)
Openalex Percentile: Top 11%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.