A Pilot Study on the Efficacy of Artificial Intelligence-Driven Monocular Three-Dimensional Conversion for Endoscopic Spatial Perception

Background: Monocular two-dimensional endoscopes inherently lack depth perception, significantly increasing the cognitive load during surgical procedures. Artificial intelligence has the potential to convert two-dimensional video feeds into stereoscopic three-dimensional views in real time, yet its depth-dependent limitations remain underexplored. This pilot study evaluated the efficacy and spatial limitations of an artificial intelligence-driven monocular three-dimensional conversion system. Methods: Six participants performed a surgical target-grasping task within a dry box simulator under three distinct visual conditions: a monocular two-dimensional baseline, an artificial intelligence-generated three-dimensional system, and a native stereoscopic three-dimensional system. Targets were placed at three specific working distances of 3 cm, 5 cm, and 10 cm, yielding a total of 90 independent trials. Results: The overall grasping success rate was 33.3% for the two-dimensional baseline, 52.2% for the artificial intelligence system, and 68.9% for the native three-dimensional system. Statistical analysis confirmed that the artificial intelligence conversion significantly improved the success rate over the standard two-dimensional environment. Furthermore, the artificial intelligence system drastically reduced the average task completion time to 5.25 seconds compared to 7.93 seconds in the two-dimensional setting. A distance-based sub-analysis revealed a notable physical limitation. The artificial intelligence system provided exceptional spatial support, comparable to native three-dimensional systems, at close working distances of 3 cm and 5 cm. However, at a deeper distance of 10 cm, the monocular depth cues diminished, leading to a decline in estimation accuracy. Conclusions: Real-time artificial intelligence-driven three-dimensional conversion successfully enhances spatial perception and operational efficiency in surgical environments. While it serves as a highly effective visual assist tool at standard close working distances, operators must remain aware of its limitations in deeper operative spaces.

Authors

Publication Details

Journal
Cureus
Published
2026-06-30
DOI
https://doi.org/10.7759/cureus.111858
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Pilot Study on the Efficacy of Artificial Intelligence-Driven Monocular Three-Dimensional Conversion for Endoscopic Spatial Perception

Yosuke Sato, Kosuke Tanaka
Cureus
Surgical Simulation and Training
article

A Pilot Study on the Efficacy of Artificial Intelligence-Driven Monocular Three-Dimensional Conversion for Endoscopic Spatial Perception

Yosuke Sato, Kosuke Tanaka
article en

Abstract

Background: Monocular two-dimensional endoscopes inherently lack depth perception, significantly increasing the cognitive load during surgical procedures. Artificial intelligence has the potential to convert two-dimensional video feeds into stereoscopic three-dimensional views in real time, yet its depth-dependent limitations remain underexplored. This pilot study evaluated the efficacy and spatial limitations of an artificial intelligence-driven monocular three-dimensional conversion system. Methods: Six participants performed a surgical target-grasping task within a dry box simulator under three distinct visual conditions: a monocular two-dimensional baseline, an artificial intelligence-generated three-dimensional system, and a native stereoscopic three-dimensional system. Targets were placed at three specific working distances of 3 cm, 5 cm, and 10 cm, yielding a total of 90 independent trials. Results: The overall grasping success rate was 33.3% for the two-dimensional baseline, 52.2% for the artificial intelligence system, and 68.9% for the native three-dimensional system. Statistical analysis confirmed that the artificial intelligence conversion significantly improved the success rate over the standard two-dimensional environment. Furthermore, the artificial intelligence system drastically reduced the average task completion time to 5.25 seconds compared to 7.93 seconds in the two-dimensional setting. A distance-based sub-analysis revealed a notable physical limitation. The artificial intelligence system provided exceptional spatial support, comparable to native three-dimensional systems, at close working distances of 3 cm and 5 cm. However, at a deeper distance of 10 cm, the monocular depth cues diminished, leading to a decline in estimation accuracy. Conclusions: Real-time artificial intelligence-driven three-dimensional conversion successfully enhances spatial perception and operational efficiency in surgical environments. While it serves as a highly effective visual assist tool at standard close working distances, operators must remain aware of its limitations in deeper operative spaces.

Cureus
Openalex Percentile: Top 6%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.