In silico–optimised RP-HPLC – FLD method coupled with MgSO <sub>4</sub> -assisted salting-out extraction for ultra-trace detection of three Fluoroquinolone antibiotics in aquatic matrices

Fluoroquinolone (FQs) antibiotics are frequently detected as emergent contaminants in aquatic environments, necessitating sensitive and reliable analytical methods for their determination. In this study, an integrated in silico and in vivo strategy was developed for the trace-level detection of ciprofloxacin (CIP), norfloxacin (NOR), and ofloxacin (OFL) in diverse water matrices. Separation and quantification were achieved using reversed-phase high-performance liquid chromatography coupled with fluorescence detection (RP-HPLC-FLD). A linear mathematical model was employed to optimise chromatographic parameters, including mobile phase composition, pH, and flow rate, reducing reliance on conventional trial-and-error approaches without compromising chromatographic performance. The optimised excitation-emission wavelength pair (λex = 290 nm; λem = 460 nm) was used for all analytes, improving instrumental stability and analytical throughput. Under gradient elution with acetonitrile and methanol at a flow rate of 1 mL min−1, CIP, NOR, and OFL were resolved at 16.68, 15.27, and 14.51 min, respectively, demonstrating high selectivity and sensitivity. Sample preparation employed a magnesium sulphate-driven dual salting-out and drying (MgSO4-D2 S) strategy, providing efficient extraction. The method showed excellent linearity (R2 = 0.99) over 250–5 ng L−1, with recoveries above 90% and precision (RSD) of 0.59–3.87%. Limits of detection were 1.88, 0.79, and 1.57 ng L−1 for CIP, NOR, and OFL, while limits of quantification were 5.70, 2.39, and 4.77 ng L−1, respectively. The method was successfully applied to river, pond, wastewater, tap water, seawater, and microcosm samples, enabling reliable trace-level monitoring of FQs residues in aquatic environmental samples.

Authors

Institutions

Publication Details

Journal
International Journal of Environmental & Analytical Chemistry
Published
2026-06-30
DOI
https://doi.org/10.1080/03067319.2026.2695743
Primary Topic
Pharmaceutical and Antibiotic Environmental Impacts
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In silico–optimised RP-HPLC – FLD method coupled with MgSO 4 -assisted salting-out extraction for ultra-trace detection of three Fluoroquinolone antibiotics in aquatic matrices

Subhankar Chatterjee, Sujan Gayen, Anwesa Guha, Moumita Mondal
International Journal of Environmental & Analytical Chemistry
Pharmaceutical and Antibiotic Environmental Impacts
article

In silico–optimised RP-HPLC – FLD method coupled with MgSO 4 -assisted salting-out extraction for ultra-trace detection of three Fluoroquinolone antibiotics in aquatic matrices

Subhankar Chatterjee, Sujan Gayen, Anwesa Guha, Moumita Mondal
article en

Abstract

Fluoroquinolone (FQs) antibiotics are frequently detected as emergent contaminants in aquatic environments, necessitating sensitive and reliable analytical methods for their determination. In this study, an integrated in silico and in vivo strategy was developed for the trace-level detection of ciprofloxacin (CIP), norfloxacin (NOR), and ofloxacin (OFL) in diverse water matrices. Separation and quantification were achieved using reversed-phase high-performance liquid chromatography coupled with fluorescence detection (RP-HPLC-FLD). A linear mathematical model was employed to optimise chromatographic parameters, including mobile phase composition, pH, and flow rate, reducing reliance on conventional trial-and-error approaches without compromising chromatographic performance. The optimised excitation-emission wavelength pair (λex = 290 nm; λem = 460 nm) was used for all analytes, improving instrumental stability and analytical throughput. Under gradient elution with acetonitrile and methanol at a flow rate of 1 mL min−1, CIP, NOR, and OFL were resolved at 16.68, 15.27, and 14.51 min, respectively, demonstrating high selectivity and sensitivity. Sample preparation employed a magnesium sulphate-driven dual salting-out and drying (MgSO4-D2 S) strategy, providing efficient extraction. The method showed excellent linearity (R2 = 0.99) over 250–5 ng L−1, with recoveries above 90% and precision (RSD) of 0.59–3.87%. Limits of detection were 1.88, 0.79, and 1.57 ng L−1 for CIP, NOR, and OFL, while limits of quantification were 5.70, 2.39, and 4.77 ng L−1, respectively. The method was successfully applied to river, pond, wastewater, tap water, seawater, and microcosm samples, enabling reliable trace-level monitoring of FQs residues in aquatic environmental samples.

International Journal of Environmental & Analytical Chemistry
Pondicherry University (IN)
Life below water, Clean water and sanitation
Openalex Percentile: Top 15%
Pharmaceutical and Antibiotic Environmental Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.