Design and Geant4 simulation of an energy degrader system for PIXE and PIGE at the TINT cyclotron facility

This study presents the design and simulation of an energy degrader system for the Thailand Institute of Nuclear Technology (TINT) cyclotron facility, developed to reduce 15–30 MeV proton beams to 2–5 MeV for PIXE and PIGE applications. SRIM and Geant4 simulations were utilized to optimize foil thickness and characterize beam dynamics. Varying the foil thickness (0.1 -1.4 mm) achieved degraded energies between 2 and 15 MeV. However, multiple Coulomb scattering increased the energy spread (1–29%) and RMS transverse emittance 80–395 mm·mrad). Four representative cases yielded energies of 11.8, 9.1, 6.3, and 2.8 MeV, with energy spread peaking at 16.9% for the lowest energy. To mitigate beam quality degradation, a two-stage collimator system was implemented. This reduced the transverse emittance by approximately 5 mm·mrad compared to a single-collimator setup, achieving proton transmission rates of 0.3–2% (0.6–4 µA from a 200 µA initial beam). Radiation safety was evaluated by mapping the neutron ambient dose equivalent, H*(10), using Geant4. Peak neutron dose exceeding 1.5 × 10−12 µSv per primary proton near the degrader assembly, confirming that local shielding with borated polyethylene is essential. These results provide benchmark beam parameters for future PIXE and PIGE applications and support the design of downstream beam transport systems, including a dipole magnet spectrometer for energy selection and analysis.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Science and Technology
Published
2026-06-30
DOI
https://doi.org/10.1080/00223131.2026.2694579
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Geant4 simulation of an energy degrader system for PIXE and PIGE at the TINT cyclotron facility

Piyanud Thongjerm, Wutthichok SANGWANG, Phalakorn Khwansungnoen, S Wonglee et al.
Journal of Nuclear Science and Technology
Radiation Therapy and Dosimetry
article

Design and Geant4 simulation of an energy degrader system for PIXE and PIGE at the TINT cyclotron facility

Piyanud Thongjerm, Wutthichok SANGWANG, Phalakorn Khwansungnoen, S Wonglee, Akkapob Ngamlamiad, Ekkachai Kongmon, Kritsada Kittimanapun, Weerawat Pornroongruengchok, Kitisak Komnoi, Khwanjira Tangpong, Thanabodee Sookchuay, Adundet Khurasi
article en

Abstract

This study presents the design and simulation of an energy degrader system for the Thailand Institute of Nuclear Technology (TINT) cyclotron facility, developed to reduce 15–30 MeV proton beams to 2–5 MeV for PIXE and PIGE applications. SRIM and Geant4 simulations were utilized to optimize foil thickness and characterize beam dynamics. Varying the foil thickness (0.1 -1.4 mm) achieved degraded energies between 2 and 15 MeV. However, multiple Coulomb scattering increased the energy spread (1–29%) and RMS transverse emittance 80–395 mm·mrad). Four representative cases yielded energies of 11.8, 9.1, 6.3, and 2.8 MeV, with energy spread peaking at 16.9% for the lowest energy. To mitigate beam quality degradation, a two-stage collimator system was implemented. This reduced the transverse emittance by approximately 5 mm·mrad compared to a single-collimator setup, achieving proton transmission rates of 0.3–2% (0.6–4 µA from a 200 µA initial beam). Radiation safety was evaluated by mapping the neutron ambient dose equivalent, H*(10), using Geant4. Peak neutron dose exceeding 1.5 × 10−12 µSv per primary proton near the degrader assembly, confirming that local shielding with borated polyethylene is essential. These results provide benchmark beam parameters for future PIXE and PIGE applications and support the design of downstream beam transport systems, including a dipole magnet spectrometer for energy selection and analysis.

Journal of Nuclear Science and Technology
Thailand Graduate Institute of Science and Technology (TH), Synchrotron Light Research Institute (TH)
Affordable and clean energy
Openalex Percentile: Top 8%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.