Investigation of the Effect of Different Voxel Sizes and Beam Fields on Dose Distribution in Small-Field Radiotherapy Treatment

This study investigates the influence of voxel size and small photon beam fields on dose distribution to determine optimal dosimetric parameters for accurate calculations in radiotherapy. Dose distributions were computed in a homogeneous water phantom using the Monte Carlo–based EGSnrc/DOSXYZnrc system with a 1 MeV photon source and beam sizes from 0.5 × 0.5 to 3 × 3 cm². Analyses at clinically relevant surface depths (0.007–0.1 cm) showed that a voxel size of 0.01 cm provides optimal accuracy across all field sizes. Beyond 0.1 cm depth, the ideal voxel size increased proportionally with both depth and beam field, ranging from 0.05 to 0.25 cm. Larger voxels caused substantial errors, reaching 5–34% in dose calculations. These findings highlight voxel size as a critical factor in small-field dosimetry and emphasize that selecting depth- and field-specific voxel dimensions can enhance dose accuracy and potentially reduce radiation-induced skin toxicity in precision radiotherapy.

Authors

Institutions

Publication Details

Journal
Celal Bayar Üniversitesi Fen Bilimleri Dergisi
Published
2026-06-30
DOI
https://doi.org/10.18466/cbayarfbe.1826799
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the Effect of Different Voxel Sizes and Beam Fields on Dose Distribution in Small-Field Radiotherapy Treatment

G Aydogdu
Celal Bayar Üniversitesi Fen Bilimleri Dergisi
Advanced Radiotherapy Techniques
article

Investigation of the Effect of Different Voxel Sizes and Beam Fields on Dose Distribution in Small-Field Radiotherapy Treatment

G Aydogdu
article en

Abstract

This study investigates the influence of voxel size and small photon beam fields on dose distribution to determine optimal dosimetric parameters for accurate calculations in radiotherapy. Dose distributions were computed in a homogeneous water phantom using the Monte Carlo–based EGSnrc/DOSXYZnrc system with a 1 MeV photon source and beam sizes from 0.5 × 0.5 to 3 × 3 cm². Analyses at clinically relevant surface depths (0.007–0.1 cm) showed that a voxel size of 0.01 cm provides optimal accuracy across all field sizes. Beyond 0.1 cm depth, the ideal voxel size increased proportionally with both depth and beam field, ranging from 0.05 to 0.25 cm. Larger voxels caused substantial errors, reaching 5–34% in dose calculations. These findings highlight voxel size as a critical factor in small-field dosimetry and emphasize that selecting depth- and field-specific voxel dimensions can enhance dose accuracy and potentially reduce radiation-induced skin toxicity in precision radiotherapy.

Celal Bayar Üniversitesi Fen Bilimleri DergisiVol. 22(2)
Manisa Celal Bayar University (TR)
Manisa Celal Bayar Üniversitesi, Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Clean water and sanitation
Openalex Percentile: Top 7%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.