Morphometric Evaluation of the Palmaris Longus Tendon and Its Adequacy for Tendon Grafting in a Turkish Cadaveric Population

AbstractObjective The Palmaris Longus (PL) tendon is a commonly used autograft in tendon reconstruction; however, the consistency of its anatomical length remains debated. This study aimed to evaluate the morphometric characteristics of the PL tendon in a Turkish cadaveric population and to determine whether it reliably meets the clinically critical graft length threshold of 120 mm (12 cm) required for delayed flexor and extensor tendon reconstructions.Methods This morphometric study included 20 adult cadaveric upper extremities. The lengths of the PL tendon and muscle belly were measured, and tendon adequacy was assessed against a predefined minimum graft length of 120 mm using a one-sample t-test. The association between muscle belly length and tendon length was analyzed using Pearson correlation.Results The mean PL tendon length was 147.58 ± 5.49 mm (range: 136.53–155.49 mm), with all specimens (100%) exceeding the 120 mm threshold. Mean tendon length was significantly greater than the reference value (p < 0.001), with a very large effect size (Cohen’s d = 5.03). The mean muscle belly length was 122.54 ± 5.02 mm. No significant correlation was observed between muscle belly length and tendon length (r = 0.010, p = 0.968).Conclusion In this cadaveric cohort, the Palmaris Longus tendon consistently provides sufficient length for standard tendon grafting procedures requiring grafts up to 12 cm. However, the absence of correlation between muscle belly size and tendon length indicates that surface anatomy is an unreliable predictor of graft adequacy. When precise graft length is critical, objective preoperative imaging should be considered.

Authors

Institutions

Publication Details

Journal
Ankara Üniversitesi Tıp Fakültesi Mecmuası
Published
2026-06-30
DOI
https://doi.org/10.65092/autfm.1847967
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Morphometric Evaluation of the Palmaris Longus Tendon and Its Adequacy for Tendon Grafting in a Turkish Cadaveric Population

Yener Yoğun, Erdinç Acar, Mustafa Yasin Hatipoğlu, Si̇mel Kendi̇r et al.
Ankara Üniversitesi Tıp Fakültesi Mecmuası
Orthopedic Surgery and Rehabilitation
article

Morphometric Evaluation of the Palmaris Longus Tendon and Its Adequacy for Tendon Grafting in a Turkish Cadaveric Population

Yener Yoğun, Erdinç Acar, Mustafa Yasin Hatipoğlu, Si̇mel Kendi̇r, Mehmet Yılmaz, Tevfik Onur Özdemir, Hasan Emre Özsoy
article en

Abstract

AbstractObjective The Palmaris Longus (PL) tendon is a commonly used autograft in tendon reconstruction; however, the consistency of its anatomical length remains debated. This study aimed to evaluate the morphometric characteristics of the PL tendon in a Turkish cadaveric population and to determine whether it reliably meets the clinically critical graft length threshold of 120 mm (12 cm) required for delayed flexor and extensor tendon reconstructions.Methods This morphometric study included 20 adult cadaveric upper extremities. The lengths of the PL tendon and muscle belly were measured, and tendon adequacy was assessed against a predefined minimum graft length of 120 mm using a one-sample t-test. The association between muscle belly length and tendon length was analyzed using Pearson correlation.Results The mean PL tendon length was 147.58 ± 5.49 mm (range: 136.53–155.49 mm), with all specimens (100%) exceeding the 120 mm threshold. Mean tendon length was significantly greater than the reference value (p < 0.001), with a very large effect size (Cohen’s d = 5.03). The mean muscle belly length was 122.54 ± 5.02 mm. No significant correlation was observed between muscle belly length and tendon length (r = 0.010, p = 0.968).Conclusion In this cadaveric cohort, the Palmaris Longus tendon consistently provides sufficient length for standard tendon grafting procedures requiring grafts up to 12 cm. However, the absence of correlation between muscle belly size and tendon length indicates that surface anatomy is an unreliable predictor of graft adequacy. When precise graft length is critical, objective preoperative imaging should be considered.

Ankara Üniversitesi Tıp Fakültesi MecmuasıVol. 79(2)
Ankara University (TR), Ankara Bilkent City Hospital (TR)
Openalex Percentile: Top 6%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.