Multi-Source Feature Fusion with Self-Supervised Contrastive Learning for AF Detection under Label Scarcity

Accurate atrial fibrillation (AF) screening from short, single-lead wearable ECG remains challenging due to noise contamination, limited computation budgets, and scarce annotations. We present a multi-source feature fusion framework that combines rhythm, morphology, and implicit representations to improve AF detection under label scarcity. The pipeline performs denoising, robust R-wave localization, and heartbeat segmentation to construct rhythm sequences and beat-level waveform inputs for downstream modeling. Complementary representations are learned from rhythm variability statistics, morphology-aware encoders, and self-supervised contrastive pretraining on external data with subsequent adaptation to the target domain. The resulting embeddings are integrated using attention-guided fusion for classification. Experiments on multiple public datasets demonstrate consistent performance in low-label settings, indicating the potential of the proposed approach for wearable AF screening. Further evaluation of computational efficiency and on-device performance is still required.

Authors

Institutions

Publication Details

Journal
AI Engineering
Published
2026-06-30
DOI
https://doi.org/10.53941/aieng.2026.100008
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Source Feature Fusion with Self-Supervised Contrastive Learning for AF Detection under Label Scarcity

Yuying Xie, Hexin Wan, Zhengyang Miao, Qi Yan et al.
AI Engineering
ECG Monitoring and Analysis
article

Multi-Source Feature Fusion with Self-Supervised Contrastive Learning for AF Detection under Label Scarcity

Yuying Xie, Hexin Wan, Zhengyang Miao, Qi Yan, Dongchen Wu, Haotian Tang, Liping Xie
article en

Abstract

Accurate atrial fibrillation (AF) screening from short, single-lead wearable ECG remains challenging due to noise contamination, limited computation budgets, and scarce annotations. We present a multi-source feature fusion framework that combines rhythm, morphology, and implicit representations to improve AF detection under label scarcity. The pipeline performs denoising, robust R-wave localization, and heartbeat segmentation to construct rhythm sequences and beat-level waveform inputs for downstream modeling. Complementary representations are learned from rhythm variability statistics, morphology-aware encoders, and self-supervised contrastive pretraining on external data with subsequent adaptation to the target domain. The resulting embeddings are integrated using attention-guided fusion for classification. Experiments on multiple public datasets demonstrate consistent performance in low-label settings, indicating the potential of the proposed approach for wearable AF screening. Further evaluation of computational efficiency and on-device performance is still required.

AI EngineeringVol. 2(1)
Northeastern University (CN)
Openalex Percentile: Top 8%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.