Influence of Metal Artifact Reduction Algorithms on the Detection of Inferior Alveolar Canal Perforations by Zirconia Implants in CBCT Images

INTRODUCTION: This study aims to evaluate the efficacy of a metal artifact reduction (MAR) algorithm in detecting contact between zirconia implants and inferior alveolar canal. MATERIALS AND METHODS: Twelve zirconia implants were placed in dry human mandibles using surgical guides, in two conditions: 1 mm above and within the canal. cone beam computed tomography (CBCT) was acquired with the MAR algorithm turned off and on. Three observers indicated whether canal damage was present using a 5-point Likert scale: 1. Definitely no contact, 2. Probably no contact, 3. Uncertain, 4. Probably contact, and 5. Definitely contact. Sensitivity and specificity were calculated and the ROC curve was used to compare the two conditions (α = 0.05). RESULTS: The area under curve (AUC) was higher in MAR On condition for all observers; however, the differences in AUC between the On and Off MAR states were not statistically significant (p > 0.05): for observer 1, AUC increased from 0.9916 (Off) to 1.0 (On); for Observer 2, it increased from 0.7666 to 0.8833; and for Observer 3, it increased from 0.95 to 1.0. Observers 1 and 3 displayed 100% sensitivity and specificity regardless of MAR activation, while for Observer 2, diagnostic sensitivity increased from 66.7% to 83.3% with MAR activation, while specificity remained constant at 80% in both conditions. CONCLUSION: For the detection of contact of the zirconia implants with the IAC, activating the MAR algorithm slightly increased the diagnostic performance metrics of CBCT images, but the differences were not statistically significant. CLINICAL RELEVANCE: Activating the MAR algorithm did not produce a statistically significant improvement in detecting contact between zirconia implants and the inferior alveolar canal.

Authors

Institutions

Publication Details

Journal
Clinical and Experimental Dental Research
Published
2026-06-30
DOI
https://doi.org/10.1002/cre2.70397
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Metal Artifact Reduction Algorithms on the Detection of Inferior Alveolar Canal Perforations by Zirconia Implants in CBCT Images

Mariangela Cernera, Parisa Soltani, Mahsa Aeinehvand, Reyhaneh Rostamian et al.
Clinical and Experimental Dental Research
Dental Radiography and Imaging
article

Influence of Metal Artifact Reduction Algorithms on the Detection of Inferior Alveolar Canal Perforations by Zirconia Implants in CBCT Images

Mariangela Cernera, Parisa Soltani, Mahsa Aeinehvand, Reyhaneh Rostamian, Gianrico Spagnuolo, Francesco Riccitiello, Amirhossein Moaddabi, Niccolò Giuseppe Armogida, Hugh Devlin, Mohammad Hossein Manouchehri, Aida Ekhtiari, Sara Rostamian
article en

Abstract

INTRODUCTION: This study aims to evaluate the efficacy of a metal artifact reduction (MAR) algorithm in detecting contact between zirconia implants and inferior alveolar canal. MATERIALS AND METHODS: Twelve zirconia implants were placed in dry human mandibles using surgical guides, in two conditions: 1 mm above and within the canal. cone beam computed tomography (CBCT) was acquired with the MAR algorithm turned off and on. Three observers indicated whether canal damage was present using a 5-point Likert scale: 1. Definitely no contact, 2. Probably no contact, 3. Uncertain, 4. Probably contact, and 5. Definitely contact. Sensitivity and specificity were calculated and the ROC curve was used to compare the two conditions (α = 0.05). RESULTS: The area under curve (AUC) was higher in MAR On condition for all observers; however, the differences in AUC between the On and Off MAR states were not statistically significant (p > 0.05): for observer 1, AUC increased from 0.9916 (Off) to 1.0 (On); for Observer 2, it increased from 0.7666 to 0.8833; and for Observer 3, it increased from 0.95 to 1.0. Observers 1 and 3 displayed 100% sensitivity and specificity regardless of MAR activation, while for Observer 2, diagnostic sensitivity increased from 66.7% to 83.3% with MAR activation, while specificity remained constant at 80% in both conditions. CONCLUSION: For the detection of contact of the zirconia implants with the IAC, activating the MAR algorithm slightly increased the diagnostic performance metrics of CBCT images, but the differences were not statistically significant. CLINICAL RELEVANCE: Activating the MAR algorithm did not produce a statistically significant improvement in detecting contact between zirconia implants and the inferior alveolar canal.

Clinical and Experimental Dental ResearchVol. 12(4)
University of Jordan (JO), Isfahan University of Medical Sciences (IR), Islamic Azad University, Science and Research Branch (IR), University of Tehran (IR), University Of Bristol Dental Hospital (GB), Dr. D.Y. Patil Vidyapeeth, Pune (IN), Federico II University Hospital (IT), University of Naples Federico II (IT), Mazandaran University of Medical Sciences (IR)
Isfahan University of Medical Sciences
Life below water
Openalex Percentile: Top 7%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.