Operating a large-diameter dual-phase liquid xenon TPC in the unshielded PANCAKE facility

Abstract Future liquid-xenon (LXe) based observatories for rare processes, such as XLZD, require testing of large components and sub-assemblies in cryogenic liquid or gaseous xenon environments. Here we present results from the stable operation of a shallow dual-phase LXe TPC with an inner diameter of 133.4 cm and a height of 3.1 cm in the unshielded PANCAKE platform, without underground suppression of cosmic-ray backgrounds. A total of 340 kg of xenon was used in the experiment, of which 127 kg constituted the active TPC mass. Measurements of the LXe purity-dependent electron lifetime and the electron drift velocity in LXe demonstrate that sensitive measurements to characterize the TPC performance are possible in a high-background environment, even with a very basic PMT-based light detection system. The threshold was around 15 keV for electronic recoils in TPC operation; it could be straightforwardly lowered by improving the light collection efficiency.

Authors

Institutions

Publication Details

Journal
The European Physical Journal C
Published
2026-06-30
DOI
https://doi.org/10.1140/epjc/s10052-026-15735-8
Primary Topic
Dark Matter and Cosmic Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operating a large-diameter dual-phase liquid xenon TPC in the unshielded PANCAKE facility

R. Glade-Beucke, J. Grigat, S. Lindemann, A. Brown et al.
The European Physical Journal C
Dark Matter and Cosmic Phenomena
article

Operating a large-diameter dual-phase liquid xenon TPC in the unshielded PANCAKE facility

R. Glade-Beucke, J. Grigat, S. Lindemann, A. Brown, M. Schümann, T.C. Luce, Jens Reininghaus, J. Müller, A. Stevens, Gnanesh Chandra Madduri
article en

Abstract

Abstract Future liquid-xenon (LXe) based observatories for rare processes, such as XLZD, require testing of large components and sub-assemblies in cryogenic liquid or gaseous xenon environments. Here we present results from the stable operation of a shallow dual-phase LXe TPC with an inner diameter of 133.4 cm and a height of 3.1 cm in the unshielded PANCAKE platform, without underground suppression of cosmic-ray backgrounds. A total of 340 kg of xenon was used in the experiment, of which 127 kg constituted the active TPC mass. Measurements of the LXe purity-dependent electron lifetime and the electron drift velocity in LXe demonstrate that sensitive measurements to characterize the TPC performance are possible in a high-background environment, even with a very basic PMT-based light detection system. The threshold was around 15 keV for electronic recoils in TPC operation; it could be straightforwardly lowered by improving the light collection efficiency.

The European Physical Journal CVol. 86(6)
University of Freiburg (DE), University of Sheffield (GB)
Deutsche Forschungsgemeinschaft, Max Planck Institute for Nuclear Physics
Openalex Percentile: Top 10%
Dark Matter and Cosmic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.