Utility of High-Resolution Semiconductor Positron Emission Tomography/Computed Tomography in the Assessment of Breast Cancer Extent: Comparison with Magnetic Resonance Imaging

OBJECTIVE: This study aims to compare the potential of whole-body silicon photomultiplier positron emission tomography/computed tomography (WB SiPM PET/CT) in the prone position with dynamic magnetic resonance imaging (MRI) in determining the extent of breast cancer. METHODS: This retrospective study included 77 patients with 84 breast cancers who underwent both PET/CT and MRI, excluding those who received neoadjuvant chemotherapy. Four tumour thresholds for 18F-fluorodeoxyglucose uptake were defined based on the mean standardised uptake value (SUVmean) and standard deviation (SD) of normal breast tissue: SUVmean+2SD, SUVmean+3SD, 1.5SUVmean+2SD, and 1.5SUVmean+3SD. Semiautomatic measurements of tumour size for each threshold and MRI were compared against pathological tumour size and analysed by menopausal status and Ki-67 expression. RESULTS: PET/CT failed to visualise two lesions. No significant differences in the image-to-pathological tumour size ratio were observed between MRI and the 1.5SUVmean+2SD. All MRI and SUV threshold measurements exhibited strong correlations with pathological size. The 1.5SUVmean+2SD demonstrated the highest pathological concordance rate, comparable to MRI. Subgroup analysis revealed that the 1.5SUVmean+2SD was superior for premenopausal patients (60.6%, p < 0.05), while MRI excelled in postmenopausal patients (61.2%). Both 1.5SUVmean+2SD and MRI achieved the highest concordance rates (62.2%) in the high-Ki-67 group. CONCLUSION: The 1.5SUVmean+2SD of prone WB SiPM PET/CT offers a diagnostic performance equivalent to MRI for assessing breast cancer extent, particularly in premenopausal patients, while MRI remains optimal for postmenopausal patients. Both modalities are also highly effective in high Ki-67 tumours. ADVANCES IN KNOWLEDGE: These findings highlight the potential of high-resolution semiconductor PET/CT for assessing breast cancer extent.

Authors

Institutions

Publication Details

Journal
British Journal of Radiology
Published
2026-06-30
DOI
https://doi.org/10.1093/bjr/tqag157
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utility of High-Resolution Semiconductor Positron Emission Tomography/Computed Tomography in the Assessment of Breast Cancer Extent: Comparison with Magnetic Resonance Imaging

Akina Miyamoto, Rika Yoshida, Takeshi Yoshizako, Nobuko Yamamoto et al.
British Journal of Radiology
Medical Imaging Techniques and Applications
article

Utility of High-Resolution Semiconductor Positron Emission Tomography/Computed Tomography in the Assessment of Breast Cancer Extent: Comparison with Magnetic Resonance Imaging

Akina Miyamoto, Rika Yoshida, Takeshi Yoshizako, Nobuko Yamamoto, Y Kaji, Hiroyuki Kuroda
article en

Abstract

OBJECTIVE: This study aims to compare the potential of whole-body silicon photomultiplier positron emission tomography/computed tomography (WB SiPM PET/CT) in the prone position with dynamic magnetic resonance imaging (MRI) in determining the extent of breast cancer. METHODS: This retrospective study included 77 patients with 84 breast cancers who underwent both PET/CT and MRI, excluding those who received neoadjuvant chemotherapy. Four tumour thresholds for 18F-fluorodeoxyglucose uptake were defined based on the mean standardised uptake value (SUVmean) and standard deviation (SD) of normal breast tissue: SUVmean+2SD, SUVmean+3SD, 1.5SUVmean+2SD, and 1.5SUVmean+3SD. Semiautomatic measurements of tumour size for each threshold and MRI were compared against pathological tumour size and analysed by menopausal status and Ki-67 expression. RESULTS: PET/CT failed to visualise two lesions. No significant differences in the image-to-pathological tumour size ratio were observed between MRI and the 1.5SUVmean+2SD. All MRI and SUV threshold measurements exhibited strong correlations with pathological size. The 1.5SUVmean+2SD demonstrated the highest pathological concordance rate, comparable to MRI. Subgroup analysis revealed that the 1.5SUVmean+2SD was superior for premenopausal patients (60.6%, p < 0.05), while MRI excelled in postmenopausal patients (61.2%). Both 1.5SUVmean+2SD and MRI achieved the highest concordance rates (62.2%) in the high-Ki-67 group. CONCLUSION: The 1.5SUVmean+2SD of prone WB SiPM PET/CT offers a diagnostic performance equivalent to MRI for assessing breast cancer extent, particularly in premenopausal patients, while MRI remains optimal for postmenopausal patients. Both modalities are also highly effective in high Ki-67 tumours. ADVANCES IN KNOWLEDGE: These findings highlight the potential of high-resolution semiconductor PET/CT for assessing breast cancer extent.

British Journal of Radiology
Shimane University (JP)
Good health and well-being
Openalex Percentile: Top 7%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.