Pulsed Infrared Emission from Magnetar 4U 0142+61 Detected by JWST

Abstract We report on a JWST observation of the magnetar 4U 0142+61 on 2024 August 18 with the Near-Infrared Camera (NIRCam). NIRCam observed the magnetar for 33 minutes in timing mode, providing a time resolution of 2.5 s. In the F410M filter (pivot wavelength 4.08 μ m), we measured the flux density f ν = 22.9 ± 0.6 μ Jy and detected pulsations at a frequency of 115.059 ± 0.035 mHz, in agreement with the magnetar’s spin period at the epoch of the JWST observation. The observed pulse profile has one peak per period (although this may be due to the poor time resolution), with a lower limit on the pulsed fraction of about 10%. We compare the IR pulse profile to the NICER and NuSTAR X-ray pulse profiles and find that the IR peak overlaps with the hard X-ray peak, suggesting a magnetospheric origin for the pulsed IR emission.

Authors

Institutions

Publication Details

Journal
The Astrophysical Journal
Published
2026-09-09
DOI
https://doi.org/10.3847/1538-4357/ae9745
Primary Topic
Pulsars and Gravitational Waves Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulsed Infrared Emission from Magnetar 4U 0142+61 Detected by JWST

Oleg Kargaltsev, B. Posselt, Jeremy Hare, George Younes et al.
The Astrophysical Journal
Pulsars and Gravitational Waves Research
article

Pulsed Infrared Emission from Magnetar 4U 0142+61 Detected by JWST

Oleg Kargaltsev, B. Posselt, Jeremy Hare, George Younes, George G. Pavlov, Alex van Kooten
article en

Abstract

Abstract We report on a JWST observation of the magnetar 4U 0142+61 on 2024 August 18 with the Near-Infrared Camera (NIRCam). NIRCam observed the magnetar for 33 minutes in timing mode, providing a time resolution of 2.5 s. In the F410M filter (pivot wavelength 4.08 μ m), we measured the flux density f ν = 22.9 ± 0.6 μ Jy and detected pulsations at a frequency of 115.059 ± 0.035 mHz, in agreement with the magnetar’s spin period at the epoch of the JWST observation. The observed pulse profile has one peak per period (although this may be due to the poor time resolution), with a lower limit on the pulsed fraction of about 10%. We compare the IR pulse profile to the NICER and NuSTAR X-ray pulse profiles and find that the IR peak overlaps with the hard X-ray peak, suggesting a magnetospheric origin for the pulsed IR emission.

The Astrophysical JournalVol. 1008(2)
Goddard Space Flight Center (US), Pennsylvania State University (US), George Washington University (US), University of Oxford (GB), University of Maryland, College Park (US), Catholic University of America (US)
National Aeronautics and Space Administration, Space Telescope Science Institute
Openalex Percentile: Top 35%
Pulsars and Gravitational Waves Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.