Dosimetric characterization of CdZnTe radiation detectors under electron-beam irradiation

With the growing complexity of modern radiotherapy, the demand for dosimeters capable of delivering real-time, high-resolution, and reliable measurements has grown significantly. Although cadmium-zinc-tellurite (CZT) detectors have emerged as potential solutions to this growing demand, the lack of comprehensive characterization data for these detectors deters their application in clinical electron-beam dosimetry, especially for high-precision tasks such as small-field and point-dose dosimetry. In this study, we systematically characterized CZT detectors, emphasizing the performance trade-offs associated with detector thickness for therapeutic electron-beam dosimetry. The performance of two CZT detectors (6 × 6 mm²), with thicknesses of 5 and 8 mm, was evaluated using a clinical linear accelerator (LINAC) over an electron energy range of 6-18 MeV. Both detectors demonstrated stable baseline performance, including proportional dose linearity (R² > 0.997), dose-rate independence, and excellent long-term stability (<1.3% variation over two months). Furthermore, a distinct thickness-dependent trade-off was identified: while both configurations exhibited highly comparable dose responses at the 6-MeV baseline, the 8-mm detector exhibited better energy capture efficiency for higher-energy electrons. By contrast, the 5‑mm detector offered enhanced angular isotropy with respect to the gantry angle as well as reduced signal variation (±3.5% vs. ± 6.4%), emerging as more suitable for rotational therapies and geometrically demanding scenarios. Additionally, a nonmonotonic energy dependence was observed, characterized by a pronounced response peak at 15 MeV, which was likely attributable to bremsstrahlung photon contamination from the LINAC head. These findings demonstrate that detector thickness serves as an application-specific optimization factor for sensitivity and angular fidelity, offering a practical framework for deploying CZT detectors in both initial clinical evaluations and challenging extra-clinical radiation environments.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-06-30
DOI
https://doi.org/10.1371/journal.pone.0349698
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric characterization of CdZnTe radiation detectors under electron-beam irradiation

H J Kim, Sangsu Kim, Chansun Park, Jung‐Yeol Yeom et al.
PLoS ONE
Advanced Radiotherapy Techniques
article

Dosimetric characterization of CdZnTe radiation detectors under electron-beam irradiation

H J Kim, Sangsu Kim, Chansun Park, Jung‐Yeol Yeom, Shinhaeng Cho, Jiwon Seo
article en

Abstract

With the growing complexity of modern radiotherapy, the demand for dosimeters capable of delivering real-time, high-resolution, and reliable measurements has grown significantly. Although cadmium-zinc-tellurite (CZT) detectors have emerged as potential solutions to this growing demand, the lack of comprehensive characterization data for these detectors deters their application in clinical electron-beam dosimetry, especially for high-precision tasks such as small-field and point-dose dosimetry. In this study, we systematically characterized CZT detectors, emphasizing the performance trade-offs associated with detector thickness for therapeutic electron-beam dosimetry. The performance of two CZT detectors (6 × 6 mm²), with thicknesses of 5 and 8 mm, was evaluated using a clinical linear accelerator (LINAC) over an electron energy range of 6-18 MeV. Both detectors demonstrated stable baseline performance, including proportional dose linearity (R² > 0.997), dose-rate independence, and excellent long-term stability (<1.3% variation over two months). Furthermore, a distinct thickness-dependent trade-off was identified: while both configurations exhibited highly comparable dose responses at the 6-MeV baseline, the 8-mm detector exhibited better energy capture efficiency for higher-energy electrons. By contrast, the 5‑mm detector offered enhanced angular isotropy with respect to the gantry angle as well as reduced signal variation (±3.5% vs. ± 6.4%), emerging as more suitable for rotational therapies and geometrically demanding scenarios. Additionally, a nonmonotonic energy dependence was observed, characterized by a pronounced response peak at 15 MeV, which was likely attributable to bremsstrahlung photon contamination from the LINAC head. These findings demonstrate that detector thickness serves as an application-specific optimization factor for sensitivity and angular fidelity, offering a practical framework for deploying CZT detectors in both initial clinical evaluations and challenging extra-clinical radiation environments.

PLoS ONEVol. 21(6)
Korea University (KR), Chonnam National University Hospital (KR), Bioengineering Center (RU)
National Research Foundation, Korea University, National Research Foundation of Korea, Chonnam National University Hwasun Hospital
Affordable and clean energy
Openalex Percentile: Top 8%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.