Experimental Study on Time-Frequency Analysis of Vibration Signals from an Active De-Icing Exciter on Transmission Lines

In traditional mechanical de-icing technologies, the time-frequency evolution and spatial propagation mechanisms of transient high-frequency impact signals in flexible transmission lines remain unclear. To address this issue, transient impact responses were experimentally investigated using a full-scale transmission line model. An active de-icing exciter, featuring controllable impact energy and the potential for sustained online operation, was independently developed. High-frequency transient acceleration signals were acquired at multiple measurement points on a 20 m single-span line. The spatial distribution and time-frequency attenuation characteristics of the impact energy were quantitatively evaluated by extracting high-order time-domain statistical features, including root mean square, kurtosis, and crest factor, together with frequency-domain analyses based on Fast Fourier Transform (FFT) and wavelet entropy. The results indicate that: (1) The exciter generated highly impulsive transient responses, with a kurtosis up to 795.3 and a crest factor approaching 40. This suggests a strong local concentration of impact energy at the excitation source, which provides a dynamic basis for analyzing potential localized stress concentration and dynamic responses of the conductor system. (2) The transmission line structure exhibited a significant low-pass filtering effect on transient high-frequency shock waves. As the shock wave propagated towards the distal end, its high-frequency components above 30 Hz were substantially attenuated, likely due to internal dry friction within the stranded conductor. Consequently, the dominant frequency decreased to a low-frequency macroscopic sway of approximately 12 Hz, indicating a reduced risk of transmitting high-frequency shock loads to distal fittings and towers. (3) Under geometric nonlinear coupling, the vertical impact energy was partially transferred to the longitudinal and lateral directions during propagation, leading to sustained out-of-plane swaying. This study reveals the signal evolution characteristics of transient impacts in overhead transmission lines and provides experimental evidence for optimizing excitation parameters and assessing the engineering safety of active impact de-icing technologies.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-06-30
DOI
https://doi.org/10.3390/s26134128
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on Time-Frequency Analysis of Vibration Signals from an Active De-Icing Exciter on Transmission Lines

凡栋 汪, Lei Ding, Mengxuan Li, Hao Wang et al.
Sensors
Vibration and Dynamic Analysis
article

Experimental Study on Time-Frequency Analysis of Vibration Signals from an Active De-Icing Exciter on Transmission Lines

凡栋 汪, Lei Ding, Mengxuan Li, Hao Wang, Bin Zhao
article en

Abstract

In traditional mechanical de-icing technologies, the time-frequency evolution and spatial propagation mechanisms of transient high-frequency impact signals in flexible transmission lines remain unclear. To address this issue, transient impact responses were experimentally investigated using a full-scale transmission line model. An active de-icing exciter, featuring controllable impact energy and the potential for sustained online operation, was independently developed. High-frequency transient acceleration signals were acquired at multiple measurement points on a 20 m single-span line. The spatial distribution and time-frequency attenuation characteristics of the impact energy were quantitatively evaluated by extracting high-order time-domain statistical features, including root mean square, kurtosis, and crest factor, together with frequency-domain analyses based on Fast Fourier Transform (FFT) and wavelet entropy. The results indicate that: (1) The exciter generated highly impulsive transient responses, with a kurtosis up to 795.3 and a crest factor approaching 40. This suggests a strong local concentration of impact energy at the excitation source, which provides a dynamic basis for analyzing potential localized stress concentration and dynamic responses of the conductor system. (2) The transmission line structure exhibited a significant low-pass filtering effect on transient high-frequency shock waves. As the shock wave propagated towards the distal end, its high-frequency components above 30 Hz were substantially attenuated, likely due to internal dry friction within the stranded conductor. Consequently, the dominant frequency decreased to a low-frequency macroscopic sway of approximately 12 Hz, indicating a reduced risk of transmitting high-frequency shock loads to distal fittings and towers. (3) Under geometric nonlinear coupling, the vertical impact energy was partially transferred to the longitudinal and lateral directions during propagation, leading to sustained out-of-plane swaying. This study reveals the signal evolution characteristics of transient impacts in overhead transmission lines and provides experimental evidence for optimizing excitation parameters and assessing the engineering safety of active impact de-icing technologies.

SensorsVol. 26(13)
Tianjin University of Science and Technology (CN), State Grid Corporation of China (China) (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 8%
Vibration and Dynamic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.