Analysis of typical cases of medical infusion pump metering acceptance in nursing scenarios

In clinical nursing practice, the precise operation of medical infusion pumps is directly related to the safety of drug administration and the effectiveness of treatment and is a key device for ensuring the quality of nursing. This study aimed to strengthen the performance control of infusion pumps in nursing scenarios through a standardized measurement acceptance process, providing reliable equipment support for clinical nursing work. 32 newly purchased medical infusion pumps were selelcted from our hospital. According to the 'Technical Specifications for Quality Inspection of Infusion Pumps and Injection Pumps (Trial)' of the military, systematic metrological acceptance was carried out for the core issues of flow indication error, pressure alarm, and equipment functional integrity in nursing operations. The initial test showed that 96.15% of the infusion pump flow parameters did not meet the standards. And there is an abnormality in the high-pressure alarm for 8 devices. After the targeted calibration method was proposed, all 32 units were qualified. Establishing a measurement and acceptance system based on nursing needs can effectively eliminate the risks of clinical use of infusion pumps and has important practical significance for improving the level of nursing safety management. Call on everyone to prioritize life above all else.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2026-06-30
DOI
https://doi.org/10.1080/10255842.2026.2672761
Primary Topic
Intravenous Infusion Technology and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of typical cases of medical infusion pump metering acceptance in nursing scenarios

Yang Li, Li Xu, Zhenwei Du, Lidong Fan et al.
Computer Methods in Biomechanics & Biomedical Engineering
Intravenous Infusion Technology and Safety
article

Analysis of typical cases of medical infusion pump metering acceptance in nursing scenarios

Yang Li, Li Xu, Zhenwei Du, Lidong Fan, Ju Qin
article en

Abstract

In clinical nursing practice, the precise operation of medical infusion pumps is directly related to the safety of drug administration and the effectiveness of treatment and is a key device for ensuring the quality of nursing. This study aimed to strengthen the performance control of infusion pumps in nursing scenarios through a standardized measurement acceptance process, providing reliable equipment support for clinical nursing work. 32 newly purchased medical infusion pumps were selelcted from our hospital. According to the 'Technical Specifications for Quality Inspection of Infusion Pumps and Injection Pumps (Trial)' of the military, systematic metrological acceptance was carried out for the core issues of flow indication error, pressure alarm, and equipment functional integrity in nursing operations. The initial test showed that 96.15% of the infusion pump flow parameters did not meet the standards. And there is an abnormality in the high-pressure alarm for 8 devices. After the targeted calibration method was proposed, all 32 units were qualified. Establishing a measurement and acceptance system based on nursing needs can effectively eliminate the risks of clinical use of infusion pumps and has important practical significance for improving the level of nursing safety management. Call on everyone to prioritize life above all else.

Computer Methods in Biomechanics & Biomedical Engineering
Army Medical University (CN), Daping Hospital (CN)
Zero hunger
Openalex Percentile: Top 13%
Intravenous Infusion Technology and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.