Electrical Impedance Tomography for Real-Time PEEP Monitoring and Atelectasis During Mask Ventilation: A Randomized Controlled Physiological Trial

BACKGROUND: The combination of high inspired oxygen fraction (FiO2) and positive-pressure mask ventilation at induction can lead to atelectasis, increasing the risk of perioperative pulmonary complications. Positive end-expiratory pressure (PEEP) may reduce atelectasis, but prior studies relied on imaging performed before or after induction rather than during ongoing ventilation. We used electrical impedance tomography (EIT) as a bedside, real-time imaging tool. We hypothesized that higher PEEP levels would improve end-expiratory lung aeration and homogenize ventilation distribution without clinically relevant hemodynamic compromise. METHODS: In this prospective, randomized controlled study, 72 adult patients undergoing elective ophthalmic surgery under general anesthesia were enrolled. The effect of three different PEEP levels (0, 5 and 8 mbar) on the distribution of lung ventilation and hemodynamic parameters during mask ventilation at anesthesia induction with 100% (FiO2) were evaluated. Patients were randomized to ascending or descending PEEP sequences to control for order effects. The primary endpoint was the occurrence and the degree of atelectasis represented by the dorsoventral ventilation gradient at each PEEP level as detected by EIT. Secondary endpoints were changes in end-expiratory lung impedance (EELI) (ratio of EELI gain to EELI loss) and changes in lung compliance (ratio of compliance gain to compliance loss) as surrogate markers for atelectasis formation. Hemodynamic parameters were monitored with noninvasive blood pressure, electrocardiography, and electrical cardiometry. RESULTS: EIT was able to show in real-time that higher PEEP levels significantly improved the mean [SD] dorsoventral ventilation gradient (0.48 [0.21] at 0 mbar vs 0.56 [0.28] at 5 mbar vs 0.63 [0.25] at 8 mbar; p<.001), increased the ratio of gain/loss of the end-expiratory lung impedance of the whole lung (3.1 [4.8] at 0 mbar vs 6.1 [8.1] at 5 mbar (~5.1 cmH2O) vs 10.5 [12.2] at 8 mbar (~8.2 cmH2O); p<.001) and increased the compliance gain/loss ratio of the whole lung (2.7 [9.2] at 0 mbar vs 3.8 [10.3] at 5 mbar vs 4.3 [11.3] at 8 mbar; p=.011), independent of the sequence of PEEP (all data dimensionless). Electrical cardiometry revealed that hemodynamic parameters decreased after induction, but these changes were not associated with specific PEEP levels. CONCLUSIONS: Using real-time bedside EIT our study demonstrates that higher PEEP levels during mask ventilation at anesthesia induction can improve ventilation distribution without adverse hemodynamic effects.

Authors

Institutions

Publication Details

Journal
Anesthesia & Analgesia
Published
2026-06-30
DOI
https://doi.org/10.1213/ane.0000000000008165
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical Impedance Tomography for Real-Time PEEP Monitoring and Atelectasis During Mask Ventilation: A Randomized Controlled Physiological Trial

A. Meyer, Petra Schiller, S Freutel, Fabian Dusse et al.
Anesthesia & Analgesia
Respiratory Support and Mechanisms
article

Electrical Impedance Tomography for Real-Time PEEP Monitoring and Atelectasis During Mask Ventilation: A Randomized Controlled Physiological Trial

A. Meyer, Petra Schiller, S Freutel, Fabian Dusse, Andrea U. Steinbicker, Sandra Emily Stoll, Anna Klug, Inéz Frerichs, Remco Overbeek, Claus Cursiefen, Vasilena Sitnilska, Lukas Wessendorf
article en

Abstract

BACKGROUND: The combination of high inspired oxygen fraction (FiO2) and positive-pressure mask ventilation at induction can lead to atelectasis, increasing the risk of perioperative pulmonary complications. Positive end-expiratory pressure (PEEP) may reduce atelectasis, but prior studies relied on imaging performed before or after induction rather than during ongoing ventilation. We used electrical impedance tomography (EIT) as a bedside, real-time imaging tool. We hypothesized that higher PEEP levels would improve end-expiratory lung aeration and homogenize ventilation distribution without clinically relevant hemodynamic compromise. METHODS: In this prospective, randomized controlled study, 72 adult patients undergoing elective ophthalmic surgery under general anesthesia were enrolled. The effect of three different PEEP levels (0, 5 and 8 mbar) on the distribution of lung ventilation and hemodynamic parameters during mask ventilation at anesthesia induction with 100% (FiO2) were evaluated. Patients were randomized to ascending or descending PEEP sequences to control for order effects. The primary endpoint was the occurrence and the degree of atelectasis represented by the dorsoventral ventilation gradient at each PEEP level as detected by EIT. Secondary endpoints were changes in end-expiratory lung impedance (EELI) (ratio of EELI gain to EELI loss) and changes in lung compliance (ratio of compliance gain to compliance loss) as surrogate markers for atelectasis formation. Hemodynamic parameters were monitored with noninvasive blood pressure, electrocardiography, and electrical cardiometry. RESULTS: EIT was able to show in real-time that higher PEEP levels significantly improved the mean [SD] dorsoventral ventilation gradient (0.48 [0.21] at 0 mbar vs 0.56 [0.28] at 5 mbar vs 0.63 [0.25] at 8 mbar; p<.001), increased the ratio of gain/loss of the end-expiratory lung impedance of the whole lung (3.1 [4.8] at 0 mbar vs 6.1 [8.1] at 5 mbar (~5.1 cmH2O) vs 10.5 [12.2] at 8 mbar (~8.2 cmH2O); p<.001) and increased the compliance gain/loss ratio of the whole lung (2.7 [9.2] at 0 mbar vs 3.8 [10.3] at 5 mbar vs 4.3 [11.3] at 8 mbar; p=.011), independent of the sequence of PEEP (all data dimensionless). Electrical cardiometry revealed that hemodynamic parameters decreased after induction, but these changes were not associated with specific PEEP levels. CONCLUSIONS: Using real-time bedside EIT our study demonstrates that higher PEEP levels during mask ventilation at anesthesia induction can improve ventilation distribution without adverse hemodynamic effects.

Anesthesia & Analgesia
Albert Einstein College of Medicine (US), Montefiore Medical Center (US), University of Cologne (DE), University Hospital Cologne (DE)
Good health and well-being
Openalex Percentile: Top 8%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.