Study on Optimal Optical Parameters for Cutting Liver Tissue with a Novel 980/1470 nm Dual-Wavelength Semiconductor Laser

Purpose: Laser–tissue interactions induce photothermal effects governed by wavelength-dependent absorption and circulation of energy. While 980 nm targets hemoglobin for hemostasis and 1470 nm targets water for vaporization, their synergistic optimization in living liver tissue remains undefined, as existing studies predominantly examine ex vivo models or single wavelengths. This study establishes quantitative relationships between laser parameters and tissue outcomes in an in vivo model. Methods: Twenty rabbits (female New Zealand White, 1.5–2 kg) underwent hepatic transection using a 400 μm bare fiber diameter (3 mm tissue distance, 10 mm/s advancement speed) in continuous-wave (CW) and pulsed-modulated (100 ms pulse, 50% duty cycle, 5 Hz) modes. Output power: 980 nm (12–160 W) and 1470 nm (6–48 W), with different dual-wavelength power ratios. Measured outcomes: cutting depth, vaporization depth, coagulation depth, and thermal injury depth (quantified by hematoxylin and eosin staining). Statistics: analysis of variance for continuous variables, chi-square/Fisher’s exact test for categorical variables, and the Mann–Whitney U test for non-normal distributions ( p < 0.05). Results: CW mode achieved greater cutting depth than pulsed-modulated mode (median 943.97 μm vs. 689.43 μm, p < 0.05). In CW mode, 1470 nm-dominated ratios (0:1, 1:1, 1:2, 1:3, 1:4) achieved greater cutting depths than 980 nm alone (1:0). Cutting depth increased with peak power from 6 to 120 W, then decreased at 160 W due to carbonization. At 24 W total power with 1:2 ratio (8 W 980 nm/16 W 1470 nm), cutting depth was 1249.3 ± 15.55 μm, vaporization depth 739.5 ± 35.32 μm, coagulation depth 1302 ± 125.44 μm, and thermal damage 1987.53 ± 154.61 μm. Conclusions: The 980/1470 nm wavelength power ratio of 8/16 W in CW mode for liver tissue cutting offers high efficiency, safety, and minimal thermal damage, providing an effective surgical energy device for minimally invasive and precise treatment.

Authors

Institutions

Publication Details

Journal
Photobiomodulation Photomedicine and Laser Surgery
Published
2026-06-30
DOI
https://doi.org/10.1177/25785478261465277
Primary Topic
Laser Applications in Dentistry and Medicine
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Optimal Optical Parameters for Cutting Liver Tissue with a Novel 980/1470 nm Dual-Wavelength Semiconductor Laser

Rongqian Wu, Lihui Pang, Mohan Lu, Yiwen Lu et al.
Photobiomodulation Photomedicine and Laser Surgery
Laser Applications in Dentistry and Medicine
article

Study on Optimal Optical Parameters for Cutting Liver Tissue with a Novel 980/1470 nm Dual-Wavelength Semiconductor Laser

Rongqian Wu, Lihui Pang, Mohan Lu, Yiwen Lu, G X Liu, Rongfeng Wang, Yi Lyu, Linxin Shen, Le Jiang, Kuiyuan Chai, Zien Xu, Meng Zhao
article en

Abstract

Purpose: Laser–tissue interactions induce photothermal effects governed by wavelength-dependent absorption and circulation of energy. While 980 nm targets hemoglobin for hemostasis and 1470 nm targets water for vaporization, their synergistic optimization in living liver tissue remains undefined, as existing studies predominantly examine ex vivo models or single wavelengths. This study establishes quantitative relationships between laser parameters and tissue outcomes in an in vivo model. Methods: Twenty rabbits (female New Zealand White, 1.5–2 kg) underwent hepatic transection using a 400 μm bare fiber diameter (3 mm tissue distance, 10 mm/s advancement speed) in continuous-wave (CW) and pulsed-modulated (100 ms pulse, 50% duty cycle, 5 Hz) modes. Output power: 980 nm (12–160 W) and 1470 nm (6–48 W), with different dual-wavelength power ratios. Measured outcomes: cutting depth, vaporization depth, coagulation depth, and thermal injury depth (quantified by hematoxylin and eosin staining). Statistics: analysis of variance for continuous variables, chi-square/Fisher’s exact test for categorical variables, and the Mann–Whitney U test for non-normal distributions ( p < 0.05). Results: CW mode achieved greater cutting depth than pulsed-modulated mode (median 943.97 μm vs. 689.43 μm, p < 0.05). In CW mode, 1470 nm-dominated ratios (0:1, 1:1, 1:2, 1:3, 1:4) achieved greater cutting depths than 980 nm alone (1:0). Cutting depth increased with peak power from 6 to 120 W, then decreased at 160 W due to carbonization. At 24 W total power with 1:2 ratio (8 W 980 nm/16 W 1470 nm), cutting depth was 1249.3 ± 15.55 μm, vaporization depth 739.5 ± 35.32 μm, coagulation depth 1302 ± 125.44 μm, and thermal damage 1987.53 ± 154.61 μm. Conclusions: The 980/1470 nm wavelength power ratio of 8/16 W in CW mode for liver tissue cutting offers high efficiency, safety, and minimal thermal damage, providing an effective surgical energy device for minimally invasive and precise treatment.

Photobiomodulation Photomedicine and Laser Surgery
First Affiliated Hospital of Xi'an Jiaotong University (CN), Xi'an Jiaotong University (CN)
Key Research and Development Projects of Shaanxi Province
Openalex Percentile: Top 7%
Laser Applications in Dentistry and Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.