Process Intensification of Tetracycline Degradation: Synergistic Electrocatalytic Ozonation and Photoelectrocatalysis in Aqueous and Organic Matrices

High Resolution Image Download MS PowerPoint Slide The persistence of antibiotics in wastewater necessitates advanced treatment strategies to reduce environmental risk. This study investigates the degradation of tetracycline (TC) using a Ti 0.7 Ru 0.3 O 2 -mixed metal oxide (MMO) anode through electrocatalysis (EC), photocatalysis (PC), ozonation (Oz), and their coupled configurations: photoelectrocatalysis (PEC) and electrocatalytic ozonation (ECOz). Water, methanol, and ethanol were used to evaluate solvent-dependent radical generation and degradation pathways in concentrated antibiotic effluents, simulating real-world postadsorption regeneration scenarios. EC achieved >98% removal in water and methanol but was limited in ethanol (92.5%) due to stable carbon-centered radical formation. Ozonation was highly effective in water (99.3%) but failed in organic media (<8%). In contrast, coupled processes (PEC and ECOz) consistently achieved ∼99% removal across all solvents. Notably, ECOz in water exhibited the highest synergy index (SI = 4.76). Mechanistic analysis via LC-MS identified key intermediates, revealing that while single processes often generated persistent and potentially more toxic byproducts, coupled systems promoted deeper oxidation toward mineralization. Effective energy consumption (EEC) calculations showed that process integration significantly improved kinetic rates, offsetting the additional power requirements. These findings demonstrate that integrating electrochemical AOPs is a robust strategy for treating concentrated antibiotic streams, bridging the gap between pollutant separation and safe environmental discharge.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-06-30
DOI
https://doi.org/10.1021/acsomega.6c04336
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Process Intensification of Tetracycline Degradation: Synergistic Electrocatalytic Ozonation and Photoelectrocatalysis in Aqueous and Organic Matrices

Michel Zampieri Fidelis, William Santacruz, Julia Faria, Artur J. Motheo
ACS Omega
Advanced oxidation water treatment
article

Process Intensification of Tetracycline Degradation: Synergistic Electrocatalytic Ozonation and Photoelectrocatalysis in Aqueous and Organic Matrices

Michel Zampieri Fidelis, William Santacruz, Julia Faria, Artur J. Motheo
article en

Abstract

High Resolution Image Download MS PowerPoint Slide The persistence of antibiotics in wastewater necessitates advanced treatment strategies to reduce environmental risk. This study investigates the degradation of tetracycline (TC) using a Ti 0.7 Ru 0.3 O 2 -mixed metal oxide (MMO) anode through electrocatalysis (EC), photocatalysis (PC), ozonation (Oz), and their coupled configurations: photoelectrocatalysis (PEC) and electrocatalytic ozonation (ECOz). Water, methanol, and ethanol were used to evaluate solvent-dependent radical generation and degradation pathways in concentrated antibiotic effluents, simulating real-world postadsorption regeneration scenarios. EC achieved >98% removal in water and methanol but was limited in ethanol (92.5%) due to stable carbon-centered radical formation. Ozonation was highly effective in water (99.3%) but failed in organic media (<8%). In contrast, coupled processes (PEC and ECOz) consistently achieved ∼99% removal across all solvents. Notably, ECOz in water exhibited the highest synergy index (SI = 4.76). Mechanistic analysis via LC-MS identified key intermediates, revealing that while single processes often generated persistent and potentially more toxic byproducts, coupled systems promoted deeper oxidation toward mineralization. Effective energy consumption (EEC) calculations showed that process integration significantly improved kinetic rates, offsetting the additional power requirements. These findings demonstrate that integrating electrochemical AOPs is a robust strategy for treating concentrated antibiotic streams, bridging the gap between pollutant separation and safe environmental discharge.

ACS Omega
Hospital Universitário da Universidade de São Paulo (BR)
Fundação de Amparo à Pesquisa do Estado de São Paulo, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Clean water and sanitation
Openalex Percentile: Top 14%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.