Endoscopic closure of a large gastric mucosal defect using a novel endoscopic suturing device in a porcine model
Management of large mucosal defects after endoscopic submucosal dissection (ESD) remains important in endoscopy. Technical complexity, limited accessibility, and cost constrain current closure platforms.[ 1 ] Although endoscopic hand suturing enables needle-and-suture closure, it requires specialized accessories and advanced expertise.[ 2 ] Here, we present a novel endoscopic suturing device for closure of large gastric defects ([ Fig. 1 ]). The device is compatible with gastroscopes with a distal outer diameter of 9.9 mm and colonoscopes with a distal outer diameter of 11.7 mm, both with a 3.2-mm working channel. Its feasibility was evaluated in a live porcine model with a large gastric defect created by ESD. Fig. 1 Schematic view of the novel endoscopic suturing device. The device comprises a control handle, transmission components, and a suture-loaded advancing assembly with a distal C-shaped opening and a handle-controlled suturing needle (fabricated by DERUI MEDICAL, Guangxi, China). Suturing was performed from proximal to distal as follows ([ Video 1 ]). The distal C-shaped opening was aligned with the wound edge, and suturing was performed by controlling the handle ([ Fig. 2a ]). After the first stitch, the endoscope was manipulated to release the knot, and the first knot was secured by tightening the suture. Continuous suturing was repeated along the defect, with gentle withdrawal of the endoscope after every two or three stitches to tighten the suture and improve apposition ([ Fig. 2b ]). Suturing was completed with 12 stitches. The excess suture was cut with scissors ([ Fig. 2c ]), and closure was completed ([ Fig. 2d ]). Video 1 Endoscopic closure of a large gastric mucosal defect using a novel endoscopic suturing device. Download Video Fig. 2 Procedure for closing a gastric defect using the novel endoscopic suturing device. ( a ) The distal C-shaped opening was aligned with the wound edge, and suturing was performed by manipulating the handle-controlled needle. ( b ) Gentle withdrawal of the endoscope tightened the suture and improved edge apposition. ( c ) The excess suture was cut with scissors after suturing. ( d ) Completed closure of the defect. Endoscopic reassessment at 1 week showed persistent close apposition of the sutured defect ([ Fig. 3 ]), without tissue tearing, knot slippage, delayed bleeding, suture loss, or other adverse events. Compared with established hand-suturing, clip-based, or tack-based methods,[ 2 ] [ 3 ] [ 4 ] this device combines tissue capture through a distal C-shaped opening with handle-controlled, needle-mediated repeated suturing under direct endoscopic visualization, potentially facilitating secure approximation of large gastric or full-thickness gastrointestinal defects. Given that endoscopic suturing has been used in procedures related to endoscopic sleeve gastroplasty,[ 5 ] this device may be explored for gastric remodeling. Fig. 3 Endoscopic follow-up at 1 week after suturing showed close apposition of the defect without complications. Endoscopy_UCTN_Code_TTT_1AO_2AO Publication History Received: 21 May 2026 Accepted after revision: 16 June 2026 Article published online: 30 June 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Authors
- Zhanhui Ye
- Siqi Wang (ORCID: https://orcid.org/0000-0001-6136-2492)
- Qiong Yang (ORCID: https://orcid.org/0000-0002-4743-934X)
- Kequan Chen (ORCID: https://orcid.org/0000-0003-1810-8987)
- Xiujie Ye
Institutions
- First Affiliated Hospital of Guangzhou Medical University (CN)
- Guangzhou Medical University (CN)
Publication Details
- Journal
- Endoscopy
- Published
- 2026-06-30
- DOI
- https://doi.org/10.1055/a-2897-7502
- Primary Topic
- Esophageal and GI Pathology
- Type
- article
- Field-Weighted Citation Impact
- 0.00