INVESTIGATION OF INDOOR HUMIDITY IMPROVEMENT USING A DESICCANT SYSTEM REGENERATED BY WASTE HEAT FROM HOME-USE SOLID OXIDE FUEL CELL COGENERATION SYSTEM

This study aims to develop a novel system that utilizes the waste heat from a Solid Oxide Fuel Cell (SOFC) for a desiccant dehumidification process, enabling stable year-round thermal energy use and efficient household energy utilization. The system was modified to use SOFC exhaust heat as the regeneration source for the desiccant unit based on polymer sorbent characteristics. Its performance was evaluated through (1) annual thermal load analysis and environmental simulation to determine applicable indoor scales, and (2) field experiments in Okinawa, Japan’s most humid region, to verify indoor humidity control effectiveness under real environmental conditions.

Authors

Institutions

Publication Details

Journal
Journal of Environmental Engineering (Transactions of AIJ)
Published
2026-06-30
DOI
https://doi.org/10.3130/aije.91.397
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

INVESTIGATION OF INDOOR HUMIDITY IMPROVEMENT USING A DESICCANT SYSTEM REGENERATED BY WASTE HEAT FROM HOME-USE SOLID OXIDE FUEL CELL COGENERATION SYSTEM

Isamu Ohta, Shuhei Yoshimoto, Koki Kikuta, Keita Mizuno et al.
Journal of Environmental Engineering (Transactions of AIJ)
Adsorption and Cooling Systems
article

INVESTIGATION OF INDOOR HUMIDITY IMPROVEMENT USING A DESICCANT SYSTEM REGENERATED BY WASTE HEAT FROM HOME-USE SOLID OXIDE FUEL CELL COGENERATION SYSTEM

Isamu Ohta, Shuhei Yoshimoto, Koki Kikuta, Keita Mizuno, Shimpei MORIMOTO
article en

Abstract

This study aims to develop a novel system that utilizes the waste heat from a Solid Oxide Fuel Cell (SOFC) for a desiccant dehumidification process, enabling stable year-round thermal energy use and efficient household energy utilization. The system was modified to use SOFC exhaust heat as the regeneration source for the desiccant unit based on polymer sorbent characteristics. Its performance was evaluated through (1) annual thermal load analysis and environmental simulation to determine applicable indoor scales, and (2) field experiments in Okinawa, Japan’s most humid region, to verify indoor humidity control effectiveness under real environmental conditions.

Journal of Environmental Engineering (Transactions of AIJ)Vol. 91(845)
Hokkaido University (JP), Misawa City Hospital (JP)
Responsible consumption and production
Openalex Percentile: Top 13%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.