Non-destructive Through-Package Assessment of Salmon Fat Content Via Electrical Impedance Spectroscopy: A Preliminary Study

This study establishes the feasibility of using electrical impedance spectroscopy (EIS) as a non-destructive technique for assessing crude fat content in packaged salmon. Whole specimens of Coho salmon and Sockeye salmon were analyzed in various anatomical positions using a parallel circular plate electrode system. The electrical impedance | Z | and parallel capacitance C p of the samples were measured at five representative frequencies between 100 Hz and 100 kHz in four progressive sample-preparation states: whole fish, half-section, fillet, and homogenized. Soxhlet extraction was applied to correlate the measured values with crude fat content, and the results were assessed using leave-one-out cross-validation (LOOCV). The resulting root mean square error of cross-validation (RMSECV), R 2 cv , and relative predictive deviation (RPD) were used as the primary prediction metrics. We found that sample thickness and tissue heterogeneity were important factors in determining prediction accuracy. Whole fish and half-section samples showed negligible correlations ( R 2 cv < 0.53, RPD values < 1.5), whereas fillet preparations showed a strong correlation for Sockeye salmon ( R 2 cv = 0.86, RPD = 2.23) and limited correlation for Coho salmon ( R 2 cv = 0.44, RPD ≈ 1.2). The homogenized samples showed the highest correlation for both species (Sockeye: R 2 cv = 0.87, RPD = 2.43; Coho: R 2 cv = 0.71, RPD = 1.72). Notably, measuring through 0.075-mm polyethylene packaging yielded promising predictive correlations, which highlights the potential of through-package assessment. Thus, this study provides preliminary evidence of the technical feasibility of rapid fat assessment for commercial seafood quality control.

Authors

Institutions

Publication Details

Journal
Food and Bioprocess Technology
Published
2026-06-30
DOI
https://doi.org/10.1007/s11947-026-04465-0
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-destructive Through-Package Assessment of Salmon Fat Content Via Electrical Impedance Spectroscopy: A Preliminary Study

Yoshio Hagura, Fung Ee Lim
Food and Bioprocess Technology
Electrical and Bioimpedance Tomography
article

Non-destructive Through-Package Assessment of Salmon Fat Content Via Electrical Impedance Spectroscopy: A Preliminary Study

Yoshio Hagura, Fung Ee Lim
article en

Abstract

This study establishes the feasibility of using electrical impedance spectroscopy (EIS) as a non-destructive technique for assessing crude fat content in packaged salmon. Whole specimens of Coho salmon and Sockeye salmon were analyzed in various anatomical positions using a parallel circular plate electrode system. The electrical impedance | Z | and parallel capacitance C p of the samples were measured at five representative frequencies between 100 Hz and 100 kHz in four progressive sample-preparation states: whole fish, half-section, fillet, and homogenized. Soxhlet extraction was applied to correlate the measured values with crude fat content, and the results were assessed using leave-one-out cross-validation (LOOCV). The resulting root mean square error of cross-validation (RMSECV), R 2 cv , and relative predictive deviation (RPD) were used as the primary prediction metrics. We found that sample thickness and tissue heterogeneity were important factors in determining prediction accuracy. Whole fish and half-section samples showed negligible correlations ( R 2 cv < 0.53, RPD values < 1.5), whereas fillet preparations showed a strong correlation for Sockeye salmon ( R 2 cv = 0.86, RPD = 2.23) and limited correlation for Coho salmon ( R 2 cv = 0.44, RPD ≈ 1.2). The homogenized samples showed the highest correlation for both species (Sockeye: R 2 cv = 0.87, RPD = 2.43; Coho: R 2 cv = 0.71, RPD = 1.72). Notably, measuring through 0.075-mm polyethylene packaging yielded promising predictive correlations, which highlights the potential of through-package assessment. Thus, this study provides preliminary evidence of the technical feasibility of rapid fat assessment for commercial seafood quality control.

Food and Bioprocess TechnologyVol. 19(7)
Hiroshima University (JP)
Hiroshima University
Life below water
Openalex Percentile: Top 12%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.