Seismic Fragility Curves of a Friction Pendulum Base Isolated Structure Under Near-Fault Ground Motion Data

Base isolation is widely recognized as one of the most effective seismic protection strategies for buildings, particularly in earthquake-prone areas. In this study, a ten-story seismically-isolated structure with curved surface friction isolators (friction pendulum bearings) is analyzed, considering two primary engineering demand parameters: maximum inter-story drift ratio and maximum isolator displacement. A set of near-fault ground motion records containing long-period velocity pulses and higher amplitudes was selected and scaled. For the seismic performance assessment of the structure, Incremental dynamic analysis is performed for each ground motion dataset. The structural response is evaluated based on predefined performance limit states. The results indicate that the maximum inter-story drift ratio remains within acceptable limits without exceeding the thresholds for extensive or collapse damage states. However, the isolator displacement demand reaches all damage state thresholds under near-fault excitations. These findings emphasize the critical role of the isolator displacement capacity in the seismic risk assessment of seismically isolated structures.

Authors

Institutions

Publication Details

Journal
Mugla Journal of Science and Technology
Published
2026-06-30
DOI
https://doi.org/10.22531/muglajsci.1865260
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic Fragility Curves of a Friction Pendulum Base Isolated Structure Under Near-Fault Ground Motion Data

Zubair Sediqi, Ebru Harmandar, Bahadır Şadan
Mugla Journal of Science and Technology
Seismic Performance and Analysis
article

Seismic Fragility Curves of a Friction Pendulum Base Isolated Structure Under Near-Fault Ground Motion Data

Zubair Sediqi, Ebru Harmandar, Bahadır Şadan
article en

Abstract

Base isolation is widely recognized as one of the most effective seismic protection strategies for buildings, particularly in earthquake-prone areas. In this study, a ten-story seismically-isolated structure with curved surface friction isolators (friction pendulum bearings) is analyzed, considering two primary engineering demand parameters: maximum inter-story drift ratio and maximum isolator displacement. A set of near-fault ground motion records containing long-period velocity pulses and higher amplitudes was selected and scaled. For the seismic performance assessment of the structure, Incremental dynamic analysis is performed for each ground motion dataset. The structural response is evaluated based on predefined performance limit states. The results indicate that the maximum inter-story drift ratio remains within acceptable limits without exceeding the thresholds for extensive or collapse damage states. However, the isolator displacement demand reaches all damage state thresholds under near-fault excitations. These findings emphasize the critical role of the isolator displacement capacity in the seismic risk assessment of seismically isolated structures.

Mugla Journal of Science and TechnologyVol. 12(1)
MEF University (TR), Applied Natural Sciences (US), Muğla University (TR)
Sustainable cities and communities
Openalex Percentile: Top 12%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.