Experimental evaluation of heat generation in bone drilling using SS316L and ZrO <sub>2</sub> drill bits across multiple speeds and drill diameters

Overheating of the bone during drilling may raise intraosseous temperature to more than 47°C, leading to osteonecrosis and compromising implant stability. Tool material, geometry and operating conditions play an important role in heat generation. Stainless steel (SS316L) is commonly used, but ZrO 2 has become a possible alternative due to its biocompatibility and lower thermal impact. Custom drill bits (2.5, 3.0 and 3.5 mm diameter; two flutes; 90° point angle; 25° helix angle) were manufactured. A five-axis CNC machine was used to perform drilling experiments on standardized polyurethane bone blocks. A feed rate of 30 mm/min and spindle speeds of 900, 1100 and 1300 r/min were used. Temperatures T max and T avg were measured using thermocouples and recorded in two trials per condition. For T max and T avg , the temperature values obtained in two repeated trials were reported as mean ± standard deviation. SS316L drills produced greater, more fluctuating thermal profiles, reaching a T max of ∼37°C at 900 r/min (2.5 mm) to 58.75°C at 1300 r/min (3.0 mm), exceeding the osteonecrosis threshold. The T avg reached up to 39°C at 1300 r/min. On the contrary, ZrO 2 drills generated lower temperatures with a T max of 31–46°C and a T avg of 29–35°C irrespective of the diameter and speed. It is worth noting that ZrO 2 drills did not surpass 47°C. Thermal response is highly dependent on drill diameter and spindle speed, but material properties are the decisive factor. ZrO 2 drills operated at lower T max and T avg than SS316L and exhibited greater thermal control, minimizing the risk of thermal osteonecrosis. Results suggest that ZrO 2 may provide a safer thermal response during the test dry-bone drilling process.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering
Published
2026-06-30
DOI
https://doi.org/10.1177/09544089261465097
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental evaluation of heat generation in bone drilling using SS316L and ZrO 2 drill bits across multiple speeds and drill diameters

Saiful Anwar Che Ghani, Worapong Sawangsri, Pakanun Wattanasinbumrung, Phanindra Addepalli et al.
Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering
Dental Implant Techniques and Outcomes
article

Experimental evaluation of heat generation in bone drilling using SS316L and ZrO 2 drill bits across multiple speeds and drill diameters

Saiful Anwar Che Ghani, Worapong Sawangsri, Pakanun Wattanasinbumrung, Phanindra Addepalli, Jay-tawee Pukrushpan, Mohd Rasidi Ibrahim
article en

Abstract

Overheating of the bone during drilling may raise intraosseous temperature to more than 47°C, leading to osteonecrosis and compromising implant stability. Tool material, geometry and operating conditions play an important role in heat generation. Stainless steel (SS316L) is commonly used, but ZrO 2 has become a possible alternative due to its biocompatibility and lower thermal impact. Custom drill bits (2.5, 3.0 and 3.5 mm diameter; two flutes; 90° point angle; 25° helix angle) were manufactured. A five-axis CNC machine was used to perform drilling experiments on standardized polyurethane bone blocks. A feed rate of 30 mm/min and spindle speeds of 900, 1100 and 1300 r/min were used. Temperatures T max and T avg were measured using thermocouples and recorded in two trials per condition. For T max and T avg , the temperature values obtained in two repeated trials were reported as mean ± standard deviation. SS316L drills produced greater, more fluctuating thermal profiles, reaching a T max of ∼37°C at 900 r/min (2.5 mm) to 58.75°C at 1300 r/min (3.0 mm), exceeding the osteonecrosis threshold. The T avg reached up to 39°C at 1300 r/min. On the contrary, ZrO 2 drills generated lower temperatures with a T max of 31–46°C and a T avg of 29–35°C irrespective of the diameter and speed. It is worth noting that ZrO 2 drills did not surpass 47°C. Thermal response is highly dependent on drill diameter and spindle speed, but material properties are the decisive factor. ZrO 2 drills operated at lower T max and T avg than SS316L and exhibited greater thermal control, minimizing the risk of thermal osteonecrosis. Results suggest that ZrO 2 may provide a safer thermal response during the test dry-bone drilling process.

Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering
Universiti Malaysia Pahang Al-Sultan Abdullah (MY), Kasetsart University (TH), Tun Hussein Onn University of Malaysia (MY)
Faculty of Engineering, Kasetsart University
Openalex Percentile: Top 7%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.