Non-invasive estimation of hemoglobin using machine learning algorithms from i-PPG and PPG signals

Significant research works have been carried out in the area of non-invasive hemoglobin estimation in recent times. The current study compares the estimation of hemoglobin from two kinds of photoplethysmogram (PPG) signals with the results obtained from the clinical laboratory tests. They are t-PPG and i-PPG signals. The former is collected using a device that utilizes the MAX30102 sensor, and the latter is collected using a smartphone. For this purpose, twenty-one volunteers aged between 20 and 54 years participated in this study. The data was collected twice on the same day with 2 hours interval. Among the volunteers five of them provided their data once. The PPG signals collected were filtered and processed to remove the noise. The features based on optical attenuation were extracted from the signals. These along with the demographic information were fed into the machine learning algorithms. The Hb values were estimated using decision trees, boosted trees, bootstrap, NTanH and XGBoost. The XGBoost model outperformed the others. The results were obtained with the R-squared values of 0.9862, 0.9812 and RMSE of 0.0489 g/dL, 0.0329 g/dL for t-PPG signals and i-PPG, respectively.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-06-30
DOI
https://doi.org/10.1038/s41598-026-58176-9
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-invasive estimation of hemoglobin using machine learning algorithms from i-PPG and PPG signals

J. B. Jeeva, A. S. Kaviya Dharshini
Scientific Reports
Non-Invasive Vital Sign Monitoring
article

Non-invasive estimation of hemoglobin using machine learning algorithms from i-PPG and PPG signals

J. B. Jeeva, A. S. Kaviya Dharshini
article en

Abstract

Significant research works have been carried out in the area of non-invasive hemoglobin estimation in recent times. The current study compares the estimation of hemoglobin from two kinds of photoplethysmogram (PPG) signals with the results obtained from the clinical laboratory tests. They are t-PPG and i-PPG signals. The former is collected using a device that utilizes the MAX30102 sensor, and the latter is collected using a smartphone. For this purpose, twenty-one volunteers aged between 20 and 54 years participated in this study. The data was collected twice on the same day with 2 hours interval. Among the volunteers five of them provided their data once. The PPG signals collected were filtered and processed to remove the noise. The features based on optical attenuation were extracted from the signals. These along with the demographic information were fed into the machine learning algorithms. The Hb values were estimated using decision trees, boosted trees, bootstrap, NTanH and XGBoost. The XGBoost model outperformed the others. The results were obtained with the R-squared values of 0.9862, 0.9812 and RMSE of 0.0489 g/dL, 0.0329 g/dL for t-PPG signals and i-PPG, respectively.

Scientific Reports
Vellore Institute of Technology University (IN)
Zero hunger
Openalex Percentile: Top 13%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.