Flow rate dependence of salbutamol dose with various valved holding chambers in vitro

BACKGROUND: Inhalation is the primary administration route for managing airway diseases like asthma and COPD. Presently, treatment protocols for management of acute obstruction in emergency care involve using either pressurized metered dose inhalers (pMDI), often with holding chambers (HC), or nebulizers. The aim of this work was to assess the impact of different inhalation patterns and specifically peak inspiratory flow rate (PIF) on drug delivery, as well as to provide a head-to-head comparison between different (HC) in combination with a salbutamol pMDI. METHODS: For the comparison we chose two reusable (Vortex and OptiChamber Diamond) and two disposable (DispoZABLE and LiteAire) HCs. The HCs were connected to an anatomical throat model, Next Generation Impactor, and breathing simulator and the deposited drug content was measured with high performance liquid chromatography. In the used inhalation patterns the PIFs were 15 l/min, 30 l/min, 60 l/min, and 80 l/min. RESULTS: All HCs decreased throat deposition by at least 80%, but throat deposition increased with higher PIF. There was some flow-dependency also in fine particle dose (FPD) but the direction of the dependency varied between the HCs. CONCLUSIONS: The performance of disposable devices in terms of flow dependency and throat deposition was similar to reusable ones.

Authors

Institutions

Publication Details

Journal
BMC Pulmonary Medicine
Published
2026-06-30
DOI
https://doi.org/10.1186/s12890-026-04456-z
Primary Topic
Pharmacological Effects and Assays
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flow rate dependence of salbutamol dose with various valved holding chambers in vitro

Péter Csonka, Mikael Csonka, Lauri Lehtimäki, Ville Vartiainen
BMC Pulmonary Medicine
Pharmacological Effects and Assays
article

Flow rate dependence of salbutamol dose with various valved holding chambers in vitro

Péter Csonka, Mikael Csonka, Lauri Lehtimäki, Ville Vartiainen
article en

Abstract

BACKGROUND: Inhalation is the primary administration route for managing airway diseases like asthma and COPD. Presently, treatment protocols for management of acute obstruction in emergency care involve using either pressurized metered dose inhalers (pMDI), often with holding chambers (HC), or nebulizers. The aim of this work was to assess the impact of different inhalation patterns and specifically peak inspiratory flow rate (PIF) on drug delivery, as well as to provide a head-to-head comparison between different (HC) in combination with a salbutamol pMDI. METHODS: For the comparison we chose two reusable (Vortex and OptiChamber Diamond) and two disposable (DispoZABLE and LiteAire) HCs. The HCs were connected to an anatomical throat model, Next Generation Impactor, and breathing simulator and the deposited drug content was measured with high performance liquid chromatography. In the used inhalation patterns the PIFs were 15 l/min, 30 l/min, 60 l/min, and 80 l/min. RESULTS: All HCs decreased throat deposition by at least 80%, but throat deposition increased with higher PIF. There was some flow-dependency also in fine particle dose (FPD) but the direction of the dependency varied between the HCs. CONCLUSIONS: The performance of disposable devices in terms of flow dependency and throat deposition was similar to reusable ones.

BMC Pulmonary Medicine
University of Helsinki (FI), Tampere University of Applied Sciences (FI), Tampere University (FI), Helsinki University Hospital (FI), Tampere University Hospital (FI), Tampere University (FI)
Openalex Percentile: Top 10%
Pharmacological Effects and Assays
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.