Development of a hemolysis filter system for the selective removal of free hemoglobin, haem and iron from blood envisaged for use in extracorporeal circuits

Hemolysis, the rupture of red blood cells, releases hemoglobin, haem, and redox-active iron into the bloodstream. When the body's scavenging capacity is overwhelmed, these species can exert deleterious effects, as seen in hemolytic disorders. Hemolysis can also occur in extracorporeal circuits due to mechanical forces acting on blood during circulation. To mitigate these effects, we developed a filter designed for integration into extracorporeal circuits that is designed to capture hemolysis-associated byproducts using immobilised ligands. The filter prototype comprises glyoxal-functionalized agarose beads covalently immobilized with three binding agents: haptoglobin (Hp, binds cell-free hemoglobin [cfHb]), human serum albumin (HSA, binds haem), and desferrioxamine (DFO, binds free iron). Ligand immobilization was optimized to achieve strong covalent attachment to the agarose matrix. Optimized immobilization produced high ligand loading per milliliter of beads (mean ± SD): Hp 74.4 ± 11.7 mg/mL, HSA 84.6 ± 8.2 mg/mL, and DFO 43.3 ± 4.8 mg/mL. In vitro studies showed removal capacities of 12.7 ± 0.2 mg/mL for cfHb, 2708.5 ± 18.5 µg/mL for haem, and 309.7 ± 13.7 µg/mL for iron. The system retained binding activity in plasma and hemolyzed whole blood, and no increase in TAT or D-dimer was detected under the tested ex vivo conditions. These findings demonstrate the potential of this affinity-based filtration system to reduce hemolysis-associated complications in extracorporeal circulation.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-06-30
DOI
https://doi.org/10.1038/s41598-026-57088-y
Primary Topic
Hemoglobin structure and function
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a hemolysis filter system for the selective removal of free hemoglobin, haem and iron from blood envisaged for use in extracorporeal circuits

Gregory J. Quinlan, Noora Naghavi, Nathan Davies, Richard Issitt et al.
Scientific Reports
Hemoglobin structure and function
article

Development of a hemolysis filter system for the selective removal of free hemoglobin, haem and iron from blood envisaged for use in extracorporeal circuits

Gregory J. Quinlan, Noora Naghavi, Nathan Davies, Richard Issitt, Karl Riley, Lisa Barbaro, Mark JD. Griffiths, Simon Davidson, John O’Neil, Alan C. Spivey, Daniel D. Melley
article en

Abstract

Hemolysis, the rupture of red blood cells, releases hemoglobin, haem, and redox-active iron into the bloodstream. When the body's scavenging capacity is overwhelmed, these species can exert deleterious effects, as seen in hemolytic disorders. Hemolysis can also occur in extracorporeal circuits due to mechanical forces acting on blood during circulation. To mitigate these effects, we developed a filter designed for integration into extracorporeal circuits that is designed to capture hemolysis-associated byproducts using immobilised ligands. The filter prototype comprises glyoxal-functionalized agarose beads covalently immobilized with three binding agents: haptoglobin (Hp, binds cell-free hemoglobin [cfHb]), human serum albumin (HSA, binds haem), and desferrioxamine (DFO, binds free iron). Ligand immobilization was optimized to achieve strong covalent attachment to the agarose matrix. Optimized immobilization produced high ligand loading per milliliter of beads (mean ± SD): Hp 74.4 ± 11.7 mg/mL, HSA 84.6 ± 8.2 mg/mL, and DFO 43.3 ± 4.8 mg/mL. In vitro studies showed removal capacities of 12.7 ± 0.2 mg/mL for cfHb, 2708.5 ± 18.5 µg/mL for haem, and 309.7 ± 13.7 µg/mL for iron. The system retained binding activity in plasma and hemolyzed whole blood, and no increase in TAT or D-dimer was detected under the tested ex vivo conditions. These findings demonstrate the potential of this affinity-based filtration system to reduce hemolysis-associated complications in extracorporeal circulation.

Scientific Reports
St Bartholomew's Hospital (GB), Children's Society (GB), Vanderbilt University (US), London Biofoundry (GB), Lung Institute (US), Roland Hill (United Kingdom) (GB), University College London (GB), Imperial College London (GB)
British Heart Foundation
Openalex Percentile: Top 10%
Hemoglobin structure and function
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.