The Use of Point-of-Care Hemoglobin Measurements in an Elderly Population with Hematological Disorders and Anemia

Background: Patients with severe chronic anemia often require frequent blood transfusions. Many are elderly with comorbidities and limited mobility, making regular hospital visits burdensome. In some cases, patients may receive transfusions despite hemoglobin levels being above the clinical threshold due to logistical challenges, leading to unnecessary exposure to risks, inefficient use of blood units, and resource strain. This study aims to evaluate the use of point-of-care (POC) hemoglobin measurements under controlled outpatient clinic conditions, as an initial step toward potential future home-based monitoring by the patients or their caregivers, with the goal of optimizing transfusion timing, aiming to reduce unnecessary hospital visits while maintaining patient safety. Methods: A total of 127 patients from a hemato-oncology outpatient clinic at Carmel Medical Center were evaluated using a nurse-operated POC device to sample capillary blood, with 236 paired measurements concurrently analyzed via venous blood in the laboratory. Demographic and clinical data were assessed to evaluate factors associated with agreement between POC and laboratory measurements. Statistical analysis included Bland–Altman plots and Pearson correlation coefficients. Results: The POC device showed a moderate correlation with laboratory results (r = 0.73, p < 0.001), with a mean difference of 1.20 g/dL (SD = 1.94 g/dL) but wide limits of agreement (−3.20 to 5.50 g/dL). No significant differences were observed across demographic or clinical subgroups. Notably, all 156 paired measurements with POC-measured hemoglobin >7 g/dL were confirmed by laboratory testing. Conclusions: Although POC hemoglobin devices are not suitable as standalone tools for routine monitoring of chronic anemia, the high negative predictive value observed at the 7 g/dL threshold suggests that they may be useful for ruling out severe anemia. If validated in larger multicenter and home-use studies, POC Hb devices might contribute to reducing unnecessary hospital visits and transfusions.

Authors

Institutions

Publication Details

Journal
Hematology Reports
Published
2026-06-30
DOI
https://doi.org/10.3390/hematolrep18040045
Primary Topic
Blood transfusion and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Use of Point-of-Care Hemoglobin Measurements in an Elderly Population with Hematological Disorders and Anemia

Ibrahim Zoubi, Meir Preis, Mouna Ballan‐Haj, Olga Valkovsky et al.
Hematology Reports
Blood transfusion and management
article

The Use of Point-of-Care Hemoglobin Measurements in an Elderly Population with Hematological Disorders and Anemia

Ibrahim Zoubi, Meir Preis, Mouna Ballan‐Haj, Olga Valkovsky, Nili Stein, Shoshan Perek, Regina Draliuk, Adi Kibari, Amir Warwar, Liat Dizengoff, Elena Mishchenko, Marwa Naamneh, Alla Kravits, Ittai Appel
article en

Abstract

Background: Patients with severe chronic anemia often require frequent blood transfusions. Many are elderly with comorbidities and limited mobility, making regular hospital visits burdensome. In some cases, patients may receive transfusions despite hemoglobin levels being above the clinical threshold due to logistical challenges, leading to unnecessary exposure to risks, inefficient use of blood units, and resource strain. This study aims to evaluate the use of point-of-care (POC) hemoglobin measurements under controlled outpatient clinic conditions, as an initial step toward potential future home-based monitoring by the patients or their caregivers, with the goal of optimizing transfusion timing, aiming to reduce unnecessary hospital visits while maintaining patient safety. Methods: A total of 127 patients from a hemato-oncology outpatient clinic at Carmel Medical Center were evaluated using a nurse-operated POC device to sample capillary blood, with 236 paired measurements concurrently analyzed via venous blood in the laboratory. Demographic and clinical data were assessed to evaluate factors associated with agreement between POC and laboratory measurements. Statistical analysis included Bland–Altman plots and Pearson correlation coefficients. Results: The POC device showed a moderate correlation with laboratory results (r = 0.73, p < 0.001), with a mean difference of 1.20 g/dL (SD = 1.94 g/dL) but wide limits of agreement (−3.20 to 5.50 g/dL). No significant differences were observed across demographic or clinical subgroups. Notably, all 156 paired measurements with POC-measured hemoglobin >7 g/dL were confirmed by laboratory testing. Conclusions: Although POC hemoglobin devices are not suitable as standalone tools for routine monitoring of chronic anemia, the high negative predictive value observed at the 7 g/dL threshold suggests that they may be useful for ruling out severe anemia. If validated in larger multicenter and home-use studies, POC Hb devices might contribute to reducing unnecessary hospital visits and transfusions.

Hematology ReportsVol. 18(4)
Technion – Israel Institute of Technology (IL), Carmel Medical Center (IL)
Openalex Percentile: Top 11%
Blood transfusion and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.